4.2 Electrical connections for standard models
L1
Fig.12 Wiring of the heaters without using remote switch
4.3 Electrical connections without using the remote switch standard models
If the heaters are to be controlled by means other than the remote switch supplied, eg BMS, then
the heat output can be selected by connecting the appropriate terminals.
WIRED TERMINALS
RAC1306
RAC1309
2 +3 + 4 or 5
6000W
9000W
2 + 4 or 5
2000W
3000W
3 + 4 or 5
4000W
6000W
Please note the ‘4’ or ‘5’ terminal must always be connected