22. If Your Heater Does Not Work
•
Check that power is available to the heater. The
LED on the front of the heater should be
illuminated.
•
Check that the thermal cut-out has not operated.
Follow the reset instructions given under the
section headed ‘Thermal Operated Cut
-
out’.
•
Check that the fuse in the spur unit has not blown.
This can be done by replacing the fuse with
another suitable fuse.
Should none of the above remedies work, then
telephone the helpline number shown in these
instructions (UK ONLY). Do not attempt to repair the
heater.
7
23. Optional PLK1 Locking Device
- Locking tab
- Locking screw
Locking screw
Locking tab
The PLK1 locking device can be used to mechanically
lock the controls to prevent tampering with settings. As it
is not supplied with the heater, kindly contact our Sales
team if required.
20. Cleaning
Always disconnect the heater from the mains before
cleaning. The heater should not require any mainte-
nance, but it is strongly advised that it is kept clean. An
occasional wipe over with a soft cloth is all that should
be necessary.
•
Do NOT use metal or furniture polish on any part of the
heater.
•
Do NOT touch the heater with wet hands or in any
way bring water into contact with it.
If the supply cord is damaged, it must be replaced by
the manufacturer or its service agent or a similarly quali-
fied person in order to avoid a hazard.
21 . Connection to the Main Supply
Electrical installation should be carried out by a compe-
tent installer, preferably registered with NICEIC (National
Inspection Council for Electrical Installation Contracting)
in accordance with the 18th edition of the IEE Wiring Reg-
ulations, (BS.7671), and any relevant Local Authority Bye-
Laws. This heater is fitted with a 3-core mains supply ca-
ble and must be permanently connected to the electrici-
ty supply via a double pole switch having 3mm gap on
each pole.
There are no exceptions.
A switched Fused Connection unit to BS.1363. Part 4 is a
recommended mains supply connection accessory to
ensure compliance with safety requirements applicable
to fixed-wiring installation.
Note:
When switched on for the first time the appliance
may emit a slight smell. This is purely the evaporation of a
fluid used in the manufacturing process.
66001080 Iss 01