background image

 

5

 

 

I3984093 Iss 01 

22. Power adapter for fixed installation 

The CRXSL controller is supplied with a power adapter that 
will fit a 35mm or a 25mm metal or dry lining back box. The 
power adapter should only be connected to a wiring 
protected by a 6A fuse or 6A circuit breaker. Connect line 
and neutral conductors to the terminal block. Please note 
that the adaptor supplied with the controller must be 
installed exactly as the figures show, otherwise the USB 
connector will not fit correctly. The centre of the back box 
must be kept clear to allow room for the USB connector.   

 

When fitting the wall bracket, ensure that the adaptor is 
installed properly and feed the cable through the centre of 
the bracket. Screw the bracket to a back box taking care 
not to damage the power adaptor or leads with long screws. 
Connect the USB cable into the power port at back of the 
controller as shown on the photo.  Check that the CRXSL is 
working.  Attach top of the CRXSL to the wall bracket and 
slowly tilt it to place observing that the USB connector is 
moving in to the opening freely.  Once the controller is in 
place secure the two screws on the bottom of the controller. 

Please note that the controller screen will take up to 
one minute to display after powering up for the FIRST 
time.

 

23. Open Window Detection 

To ensure you don’t waste energy on heating the outside 
world, the heater is equipped with optional open / 
closed window detection. The heater recognises sudden 
drops in temperature when a window or a door is 
opened and turns the heating off to save energy. When 
the window is closed, the heater will automatically  
detect a temperature rise,  and switch itself back on. 
Once enabled in the setup menu, the open window  
detection is fully automatic and does not require any 
human intervention to be activated.   

 

 Setting-up Open Window Detection 
The system has been factory set to default time and  
temperature values. If necessary, all values can be  
adjusted. When the heating is on, open window  
detection sensor will automatically switch the heater off 
when it detects a fall in temperature of 2

°

C in less than 

10 minutes (this temperature can be changed in menu 7 
and time in menu 6). If a temperature rise of 2

°

C in less 

than 30 seconds is detected, the heater will switch itself 
back on (this temperature can be changed in menu 9 
and time in menu 8). 

24. Setup menu 

1. 

Touch and hold      and      icons together for 10 
seconds. 

2. 

The CRXSL will enter the setup menu. 

3. 

Use      and      to change a value. 

4. 

Use      to scroll between the settings. 

 

01 – temperature calibration 
The temperature reading has been factory calibrated but if 
for any reason it needs adjusting (better accuracy required, 
to suit different position in the room etc.) The reading can be 
recalibrated in 0.5 degrees steps. 

Please note that if the unit is powered by the power adapter, the 
temperature reading REQUIRES recalibration. Lower the value by 1.5 
degrees.
 

 

02 – change between degrees Celsius or Fahrenheit 

 

03 – set minimum temperature 
        (- - - = heating OFF, 4deg = frost protection) 

 

04 – set maximum temperature 

 

05 - information about the software version 

06 - 0 or 1 manual mode enable / disable 

07 - open window detection  0 = off,  1 = on 

08 - 600 - open window detection time 600 seconds 

09 - 2 - temperature drop of 2°C in the detection time 

10 - 30 - closed window detection time of 30 seconds 

11 -  2 - temperature rise of 2°C in the detection time

 

22. Power adapter for fixed installation (cont’d) 

locking screws 

USB power ports 

temperature sensor 

wall fixing 

wall fixing 

Отзывы: