![Consair CAMU D2 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/consair/camu-d2/camu-d2_instruction-manual_2654949007.webp)
5
Consair CAMU D2
11
1
2
3
4
6
7
8
9
Working area
12
13
•
Keep the mixing container in the
working area.
•
Carry out all work phases between
the air-guiding doors and as close
to the suction inlet as possible.
•
Dust is produced when the bag is
opened, closed, or emptied and
when dry matter is mixed.
10
5
14
Operating button
Pre-filter indicator
light
Main filter indicator
light
Figure 1
Figure 2 – Operating button and indicator lights
Figure 3 – Interpretation of the indicator lights
1.
Filter enclosure latch
2. Main filter enclosure
3. Intermediate filter enclosure frame
4. Pre-filter enclosure
5. Suction air
6. Air-guiding/splashguard door
7. Magnetic hinge
8. Locking screw of the air-guiding doors
9. LED work light, 10 W
10. Differential filter pressure
measurement tube
11. Operating button and filter indicator
lights
12. Tow bar
13. Push handle
14. Exhaust air
15. Stair glide
16. Socket for the power mixer
17. Type plate, serial number
18. Power cord
Green = Filter OK
Orange = Filter saturation rate over 70%
Red = Full -> Replace the filter
•
The indicator lights are constantly on when the
device is running and the suction is on.
•
The indicator lights are flashing when the device is
in the standby mode.
•
The device indicates fault modes with two flashing
red indicator lights.
See page 4, section 8.5.
15
16
17