Consair CAMU D2 Скачать руководство пользователя страница 10

8

Consair CAMU D2

11.1 Transportation at the construction site

The CAMU D2 source extractor has been designed so that 

only one person is required for its transfer and transporta-

tion. Thanks to the large 10" tyres, stair glides, tow bar, and 

push  handles,  the  device  can  also  be  moved  in  stairs  by  a 

single person.

On a rough surface, pulling is the easiest way to move the 

device. The rubber buffers in the front corners can be used 

as auxiliary carry handles, if necessary.

• 

Do not place heavy objects on top of the device.

• 

The device has not been designed for the transporta-

tion of goods.

11.2 Transportation in the cargo space of a vehicle

Primarily, the device is to be transported in an upright posi-
tion. Always strap the device to the cargo space for trans-

portation. The tubular frame of the device is well suited for 

securing.  

• 

Always secure the device by the tubular frame.

• 

Secure the device primarily so that the front of the 
device is facing a wall.

• 

If the device contains used filters, do not place it so 

that the front of the device is facing the floor. The 
filters may release dust into the cargo space of the 
vehicle.

• 

Do not remove the main filter from the device for 
transportation, since the removal of the filter pre-
vents the components from locking into their place 
and may cause components to come loose during 
transportation.

• 

Do not tighten the cargo straps so that the frame, 
filter enclosures, or doors of the device become bent.

• 

When the device is transported on a platform, it must 
be ensured that the air-guiding/splashguard doors re-
main closed by using, e.g., a quick-release cargo strap 
that goes around the device.

11.3 Mechanical lifting

The device has not been designed to be lifted mechanically, 
and it does not contain a lifting lug intended for mechanical 
lifting. The detachable parts of the device may cause seri-
ous injuries if they fall down.

11

Transportation

13

Technical data

Height   

 

 

1,150 mm

Width   

 

 

580 mm

Depth with the splashguard doors closed 
 

 

 

 

600 mm

Depth of the splashguard doors  390 mm

Height of the suction inlet 

375–585 mm

Weight (when fully operational)  28.5 kg

Operating voltage 

 

200–240 V

Rated frequency  

 

50–60 Hz

Power consumption 

 

0.8 A

Capacity 

 

 

180 W

IP rating  

 

 

IP21

Electrical outlets  

 

2  pcs  with  protective  

 

 

 

 

earthing**

Air volume 

 

 

500 m

3

/h*

Sound power level 

 

Lw(A) xx dB

Main filter 

 

 

F9

Pre-filter 

 

 

G4

*The air volume and air flow rate have been optimised for 
source extraction, and they remain unaltered for the entire 
service life of the filters.

**The maximum wattage for the coupled devices is 3,000 
W.  The connection of extension cords is forbidden.

The  CAMU  D2  source  extractor  has  been  designed  for  in-

door use and to be stored in dry and warm indoor conditions. 

The  device  withstands  cold  storage  to  a  limited  degree. 
Moisture and freezing water may damage both the device 

and the filters.

When  the  device  is  transferred  from  cold  conditions  to  a 

warm  facility,  the  temperature  of  the  device  must  be  al-
lowed to even out to the ambient temperature for at least 
30 minutes before implementation. This way, the air humid-
ity that may have condensed on the filter surfaces has time 
to dry and the aggregate dust that solidifies due to moisture 
does not clog the filters.

• 

The device has been designed to be stored in dry and 

warm indoor conditions.

• 

Do not store the device outside without weather 
protection.

12

Storage

Содержание CAMU D2

Страница 1: ...4 2019 Consair CAMU D2 FI K ytt ohje Original SV Bruksanvisning EN Instructions DE Gebrauchsanweisung Source extractor for dust control in dry mix blending...

Страница 2: ...Manufacturer Consair Oy Lapinlahdenkatu 16 FI 00180 Helsinki Finland info consair fi consair eu...

Страница 3: ...0 Contents 1 Consair CAMU D2 Transportation at the construction site Transportation in the cargo space of a vehicle Mechanical lifting Cleaning of the device Cleaning of the engine bay Replacement of...

Страница 4: ...is suitable for use in both construction and renovation sites This instruction manual describes the operation of the Con sair CAMU D2 source extractor In this manual it is also re ferred to as the de...

Страница 5: ...cator light in the control panel indicates that a filter has become clogged The device may not be used without filters Do not attempt to clean the filters as cleaning may damage the filter material Cl...

Страница 6: ...s running and the suction is on the indicator lights and the work light are on When the device is in the stand by mode the indicator lights flash simultaneously and the work light is off 8 4 Work ligh...

Страница 7: ...ter enclosure frame 4 Pre filter enclosure 5 Suction air 6 Air guiding splashguard door 7 Magnetic hinge 8 Locking screw of the air guiding doors 9 LED work light 10 W 10 Differential filter pressure...

Страница 8: ...be first passed through the washer and then the door panels and the tubular frame The heads of the pins are to be bent around the tubular frame 10 Maintenance 6 Consair CAMU D2 9 1 Filter types and ca...

Страница 9: ...7 Consair CAMU D2 Figure 4 Pre filter replacement 2 3 4 1 2 Figure 5 Pre filter replacement Figure 6 Replacement of the panels in the air guiding doors 6 A 6 B 1 3...

Страница 10: ...a quick release cargo strap that goes around the device 11 3 Mechanical lifting The device has not been designed to be lifted mechanically and it does not contain a lifting lug intended for mechanica...

Страница 11: ...t of the device This reduces the device s capacity to transfer air which means that less dust can be collected with the filters The wiring harness or control unit of the device may have become damaged...

Страница 12: ...4 35 EC complies with the relevant provisions of the EMC Directive 2014 30 EC on electromagnetic compatibility On behalf of Consair Oy signed by Place time Manufacturer authorised representative Signa...