24
Intended Use
The Fidel Power Amplifier 2x 500 W serves to amplify low-level audio signals in semi-
professional respectively professional audio systems and is interposed between the
signal source to be amplified and the loudspeakers.
The power amplifier is designed for loudspeakers with a minimum impedance of 4
Ohm. The appliance may only be used with a low-level audio source.
The product may only be connected to 230V~/50Hz (10/16 A) AC voltage and an
earthed wall socket.
Use is only permitted in closed rooms, meaning not out in the open. The contact with
moisture, e.g. in bathrooms and similar rooms has to be avoided at all cost.
Another use than the one described above leads to damages to the product and is
also associated with dangers like short circuit, fire, electric shock, etc. The entire
product may not be altered respectively modified and the casing may not be opened.
The safety notices have to be observed under all circumstances!
Individual Parts
see fold-out page
1.
Air intake opening
11. Switch SIGNAL SMART
2.
LED BRIDGE
12. Speaker outputs SPEAKON
3.
LEDs SIGNAL
13. Speaker output clamps
4.
LEDs POWER
14. Safety clamp
5.
Power switch
15. Ventilator openings
6.
Volume control
16. Switch SENSITIVITY
7.
LEDs PROTECT
17. GROUND LIFT switch
8.
LEDs LIMIT
18. Mains Connection
9.
Input jacks XLR
19. LED V.PROTECT
10. Input jack plugs
41
Technical Data
Operating voltage:
230V~/50Hz
Power consumption
3600 W max.
Fuse
T 15 A
Input sensitivity
0.775 / 1.2 / 2.45 V (switchable)
Input impedance
10 kOhm (asymmetrical)
20 kOhm (symmetrical)
Output power
2 x 1200 W on 8 Ohm
2 x 1800 W on 4 Ohm
1 x 3600 W on 8 Ohm
Frequency range
20 – 20,000 Hz (+/- 0.5 dB)
Distortion factor
< 0.05 %
S/N ratio
> 100 dB
Channel separation
> 60 dB (1 kHz)
> 50 dB (10 kHz)
Rise time
40V/µs
Ventilators
2 units, temperature control