29
11.2 Special Commands
There are commands that are so important that they deviate from the command format from
the previous chapter on purpose. These commands are:
ALARM ENABLE #1513
ALARM ENABLE #1513
This command is used to switch the alarm mode on or off. The effects this has on the product
behaviour were already described in the corresponding chapter on the subject of „Product
Status and Mode“.
STATUS #1513
This command returns a summary of the most important settings and conditions of the device.
An example for this is presented in the following (deviations possible depending on firmware
version).
Answer:
GKA100 1.xx
Product name, firmware version
…………………..
12:47 08.09.11
hour/minute and date
Alarm: off
„off“ = Alarm deactivated (DISABLE)
GSM: 63%
GSM signal strength
Batt: 100%
Battery status
Area: off
Area/zone monitoring off
Receiv.: 5/1
Motion sensor sensitivity 5 - 10
Volt.: 12.2 V
Voltage of the power supply
(when display below 5 V, then in battery mode!)
Hold Alarm: off
Hold alarm is switched off
IN1: low
Condition at input IN1: Low level
IN2: high
Condition at input IN2: High level
OUT1: off
Output OUT1 off (relay)
OUT2: on
Output OUT2 on (relay)