• Open the connection compartment at the bottom with a screw

driver.

• Connect the low-voltage plug of the power supply unit to the

socket “DC JACK”. (see Figure B right)

• Insert the antenna in the connection “ANTENNA” (see Figure

B right)

• Close the connection compartment by re-attaching the lid.
• Plug the power supply unit into a household mains socket 

230 V/AC 50 Hz.

• Switch on the Additional Radio Alarm Siren by bringing the

“ON/OFF” switch in to the position “ON”. The LED “ON”
flashes as soon as the radio alarm siren is switched on and is
supplied with power.

Acquiring of the Additional Radio Alarm Siren by the
alarm receiver

After correct installation and connection of the Additional Radio Alarm Siren, the radio alarm
siren can be acquired by the radio alarm receiver.

Proceed as follows to programme the radio alarm siren to the alarm system:

• Make sure the Additional Radio Alarm Siren is supplied with power and switched on (“ON/OFF”

switch must be in position “ON”).

• Open the connection case at the bottom with a screw driver.
• Press and hold the “LEARN” button in the connection case. The radio alarm siren emits beeps,

you are in the acquisition mode. The LED “ON” blinks.

• Press the “ARM” button of your Additional Radio Alarm Siren and enter the master code, while

keeping the “LEARN” button of the Additional Radio Alarm Siren pressed.

• As soon as the acquisition is completed the Additional Radio Alarm Siren  stops beeping and

a long beep can be heard. The LED “ON” stops blinking and goes out.

• Close the connection compartment.

Behaviour in the event of an alarm

As soon as the Additional Radio Alarm Siren triggers an alarm the Additional Radio Alarm Siren
also emits an acoustic alarm (a short delay is possible; depending on the operating conditions). 
In the event of an alarm, the LEDs “LO BATT”, “ON” and “ARM” blink.

The acoustic alarm can be stopped by e.g. deactivating the alarm system.
Please note the operating instructions of your alarm system.

Replacing the battery

If the battery is low, the LED “LO BATT” flashes. In this event, the internal 9V battery should be
replaced to further ensure correct operation.

• Remove the housing cover at the rear side by removing the screws.
• Take out the used 9V battery and replace it by a new one of the same type.
• Insert the battery in the provided battery case.
• Re-attach the housing cover and fasten the  screws.

The service life of a battery is ca. 2 years if the battery is only used as backup.The
service life of a battery is ca. 2 years if the battery is only used as backup.

Maintenance and cleaning

Except for replacing the batteries as described the device is maintenance-free.
To clean the outside of the product, a dry, soft clean cloth is sufficient. Do not use any aggressive
cleaning agents.

Disposal

a) In general

Dispose of the unserviceable product according to the relevant statutory regulations.

b) Batteries and rechargeable batteries

As a consumer you are required (Battery Directive) to responsibly dispose of all used batteries
and rechargeable batteries; it is forbidden to throw them away with the normal household
waste!

Contaminated batteries/rechargeable batteries are labelled with these symbols to
indicate that disposal in the domestic waste is forbidden. The designations for the
heavy metals involved are: Cd = cadmium, Hg = mercury, Pb = lead. 

Used batteries, rechargeable batteries as well as coin cells can be returned to
collection points in your municipality, our stores or wherever batteries/rechargeable
batteries/coin cells are sold!

You thus fulfil the legal requirements and make your contribution to protecting the environment!

Technical data

a) Additional Radio Alarm Siren 

Power supply: ......................................................1 x 9V battery
Sound volume: ....................................................Ca. 110 dB
Range:..................................................................Up to 100m (free field)
Frequency: ..........................................................433 MHz
Dimensions (W x H x D):......................................160 x 108 x 27 mm
Weight: ................................................................approx. 180 grams (excl. batteries)
Operating temperature: ........................................-20°C to 60°C

b) Power supply unit

Input:  ..................................................................230 V/AC 50 Hz
Output:  ................................................................12 V/DC 200 mA

Declaration of conformity

We, Conrad Electronic, Klaus-Conrad-Straße 1, -92240 Hirschau, hereby declare that this pro-
duct adheres to the fundamental requirements and the other relevant regulations of Directive
1999/5/EC.

You can find the declaration of conformity at www.conrad.com.

These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240
Hirschau (www.conrad.com). 

All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or
the capture in electronic data processing systems require the prior written approval by the editor.
Reprinting, also in part, is prohibited. 

These operating instructions represent the technical status at the time of printing. Changes in 
technology and equipment reserved. 

© Copyright 2012 by Conrad Electronic SE. 

Figure B

Содержание 75 15 94

Страница 1: ...s sen werden Wenn anzunehmen ist dass ein gefahrloser Betrieb nicht mehr m glich ist so ist das Ger t au er Betrieb zu setzen und gegen unbeabsichtigten Betrieb zu sichern Das Steckernetzteil darf nie...

Страница 2: ...eine neue 9V Blockbatterie Legen Sie die Batterie in das vorgesehene Batteriefach Legen Sie den r ckseitigen Geh usedeckel wieder auf und befestigen Sie die Geh use schrauben Die Batterielebensdauer...

Страница 3: ...ousehold 230V 50Hz mains socket If you have reason to assume that safe operation is no longer possible dis connect the device immediately and secure it against inadvertent operation Never plug in or r...

Страница 4: ...e provided battery case Re attach the housing cover and fasten the screws The service life of a battery is ca 2 years if the battery is only used as backup The service life of a battery is ca 2 years...

Страница 5: ...eu lev e peuvent l endommager L adaptateur d alimentation est conforme la classe de protection II Il ne doit tre raccord qu une prise de courant domestique standard de 230V 50Hz Lorsque le fonctionnem...

Страница 6: ...is Retirer la pile 9 V us e et la remplacer par une pile bloc 9 V neuve Ins rer la pile dans le compartiment piles pr vu Reposer le couvercle du bo tier l arri re et serrer les vis du bo tier La dur e...

Страница 7: ...ntact 230V 50Hz Schakel het apparaat uit en beveilig het tegen onbedoeld gebruik wanneer aangenomen kan worden dat veilig gebruik niet meer mogelijk is Zorg dat uw handen droog zijn als u de netvoedin...

Страница 8: ...Haal de verbruikte 9 V blokbatterij eruit en vervang deze door een nieuwe 9 V blokbatterij Plaats de batterij in het daarvoor bestemde batterijvak Plaats het deksel aan de achterkant van de behuizing...

Отзывы: