![Conrad 75 15 94 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/conrad/75-15-94/75-15-94_quick-start-manual_2654425004.webp)
• Open the connection compartment at the bottom with a screw
driver.
• Connect the low-voltage plug of the power supply unit to the
socket “DC JACK”. (see Figure B right)
• Insert the antenna in the connection “ANTENNA” (see Figure
B right)
• Close the connection compartment by re-attaching the lid.
• Plug the power supply unit into a household mains socket
230 V/AC 50 Hz.
• Switch on the Additional Radio Alarm Siren by bringing the
“ON/OFF” switch in to the position “ON”. The LED “ON”
flashes as soon as the radio alarm siren is switched on and is
supplied with power.
Acquiring of the Additional Radio Alarm Siren by the
alarm receiver
After correct installation and connection of the Additional Radio Alarm Siren, the radio alarm
siren can be acquired by the radio alarm receiver.
Proceed as follows to programme the radio alarm siren to the alarm system:
• Make sure the Additional Radio Alarm Siren is supplied with power and switched on (“ON/OFF”
switch must be in position “ON”).
• Open the connection case at the bottom with a screw driver.
• Press and hold the “LEARN” button in the connection case. The radio alarm siren emits beeps,
you are in the acquisition mode. The LED “ON” blinks.
• Press the “ARM” button of your Additional Radio Alarm Siren and enter the master code, while
keeping the “LEARN” button of the Additional Radio Alarm Siren pressed.
• As soon as the acquisition is completed the Additional Radio Alarm Siren stops beeping and
a long beep can be heard. The LED “ON” stops blinking and goes out.
• Close the connection compartment.
Behaviour in the event of an alarm
As soon as the Additional Radio Alarm Siren triggers an alarm the Additional Radio Alarm Siren
also emits an acoustic alarm (a short delay is possible; depending on the operating conditions).
In the event of an alarm, the LEDs “LO BATT”, “ON” and “ARM” blink.
☞
The acoustic alarm can be stopped by e.g. deactivating the alarm system.
Please note the operating instructions of your alarm system.
Replacing the battery
If the battery is low, the LED “LO BATT” flashes. In this event, the internal 9V battery should be
replaced to further ensure correct operation.
• Remove the housing cover at the rear side by removing the screws.
• Take out the used 9V battery and replace it by a new one of the same type.
• Insert the battery in the provided battery case.
• Re-attach the housing cover and fasten the screws.
☞
The service life of a battery is ca. 2 years if the battery is only used as backup.The
service life of a battery is ca. 2 years if the battery is only used as backup.
Maintenance and cleaning
Except for replacing the batteries as described the device is maintenance-free.
To clean the outside of the product, a dry, soft clean cloth is sufficient. Do not use any aggressive
cleaning agents.
Disposal
a) In general
Dispose of the unserviceable product according to the relevant statutory regulations.
b) Batteries and rechargeable batteries
As a consumer you are required (Battery Directive) to responsibly dispose of all used batteries
and rechargeable batteries; it is forbidden to throw them away with the normal household
waste!
Contaminated batteries/rechargeable batteries are labelled with these symbols to
indicate that disposal in the domestic waste is forbidden. The designations for the
heavy metals involved are: Cd = cadmium, Hg = mercury, Pb = lead.
Used batteries, rechargeable batteries as well as coin cells can be returned to
collection points in your municipality, our stores or wherever batteries/rechargeable
batteries/coin cells are sold!
You thus fulfil the legal requirements and make your contribution to protecting the environment!
Technical data
a) Additional Radio Alarm Siren
Power supply: ......................................................1 x 9V battery
Sound volume: ....................................................Ca. 110 dB
Range:..................................................................Up to 100m (free field)
Frequency: ..........................................................433 MHz
Dimensions (W x H x D):......................................160 x 108 x 27 mm
Weight: ................................................................approx. 180 grams (excl. batteries)
Operating temperature: ........................................-20°C to 60°C
b) Power supply unit
Input: ..................................................................230 V/AC 50 Hz
Output: ................................................................12 V/DC 200 mA
Declaration of conformity
We, Conrad Electronic, Klaus-Conrad-Straße 1, -92240 Hirschau, hereby declare that this pro-
duct adheres to the fundamental requirements and the other relevant regulations of Directive
1999/5/EC.
☞
You can find the declaration of conformity at www.conrad.com.
These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240
Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or
the capture in electronic data processing systems require the prior written approval by the editor.
Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in
technology and equipment reserved.
© Copyright 2012 by Conrad Electronic SE.
Figure B