Handling

•  Never use the product immediately after it has been brought from a cold to a warm room. 

This can cause condensation which may, under adverse circumstances, destroy the device.

•  Let the product first reach room temperature. This may take several hours.
•  Do not open the enclosure! Have maintenance or repair services done by a specialist 

workshop only.

•  Avoid the following adverse conditions at the location where the product is placed, and during 

transport:

 - wetness or high humidity
 - extreme cold or heat
 - dust or flammable gases, vapors or solvents
 - strong vibrations
 - strong magnet fields, such as near machines or speakers
 - When installing/operating the product, make sure the USB cable does not get twisted, bent 

or squeezed.

Maintenance and cleaning

•  Disconnect the microscope camera from the power supply.
•  Occasionally check the optics of the microscope camera, and remove any dust or dirt.
•  Use a proper lens-cleaning tool, such as a clean soft brush. Do not apply pressure to the 

optics/mechanism, as it might otherwise get damaged or the lens could get scratched.

Disposal

Electronic devices are recyclable waste and must not be disposed of in the household 

waste.
At the end of its service life, dispose of the product according to the relevant statutory 

regulations.

You thus fulfil your statutory obligations and contribute to the protection of the environment.

Technical data

Operating voltage ......................5 V/DC (via USB)
Current consumption .................approx. 450 mA
USB connection .........................USB2.0/USB3.0
Sensor .......................................max. 2 MP (1600 x 1200 dpi)
Video resolution .........................1600 x 1200 dpi, 1280 x 960 dpi,   

...................................................

800 x 600 dpi, 640 x 480 dpi

Photo resolution .........................1600 x 1200 dpi, 1280 x 960 dpi,

...................................................

800 x 600 dpi, 640 x 480 dpi

Color space ...............................RGB, 24 bit
Photo format ..............................BMP, JPG 
Video format ..............................AVI
Frame rate .................................30 frames/s
White balance ............................automatic
Exposure ...................................automatic
Lighting ......................................8 LEDs
Magnification factor ...................15 – 65x, 225x
Focus range ...............................0 – 150 mm (at 15 – 65x) 

...................................................

0 mm (at 225x)

System requirements .................Windows

®

 XP (Home, Pro, with SP2, SP3, only 32 Bit),  

...................................................

Vista™ (32 / 64 Bit), 7 (32 / 64 Bit), 8

Operating conditions ..................0 to +60 °C, 0 – 85 % RH
Storage conditions .....................-10 to +70 °C, 0 – 85 % RH
Dimensions (Ø x L) ....................approx. 32 x 132 mm
Weight .......................................approx. 105 g (without equipment)

Содержание 44 01 43

Страница 1: ...opkamera oder das zu betrachtende Objekt bis das Bild nach Wunsch ausgerichtet ist Achten Sie darauf dass kein Gegenstand die Optik ber hrt da dies zu einer Besch digung f hren kann Fassen Sie auch ni...

Страница 2: ...en oder Lautsprechern Achten Sie beim Aufstellen Betrieb des Produkts darauf dass das USB Kabel nicht berdreht geknickt oder gequetscht wird Wartung und Reinigung Trennen Sie die Mikroskopkamera von d...

Страница 3: ...image has been aligned as desired Make sure no object comes in contact with the optics as otherwise damage might be caused Also do not reach into the optics the lens would become dirty Use the snapsho...

Страница 4: ...ot get twisted bent or squeezed Maintenance and cleaning Disconnect the microscope camera from the power supply Occasionally check the optics of the microscope camera and remove any dust or dirt Use a...

Страница 5: ...e ou l objet observer jusqu ce que l image soit orient e comme vous la souhaitez Assurez vous qu aucun objet ne touche l optique car cela pourrait causer des dommages De plus ne touchez pas l objectif...

Страница 6: ...que le c ble USB ne soit pas entortill pli ou coinc Entretien et nettoyage D branchez la cam ra microscope de l alimentation lectrique V rifiez de temps autre l optique de la cam ra microscope enlevez...

Страница 7: ...cten met de optica in aanraking komen dit kan schade veroorzaken Raak de optica tevens niet aan de lens kan worden bevuild Gebruik de snapshot knop 5 bovenaan de microscoopcamera om de functiefunctie...

Страница 8: ...kers Tijdens het installeren gebruiken van het product zorg dat de USB kabel niet word gebogen verdraaid of geplet Onderhoud en reiniging Koppel de microscoopcamera van de voeding los Controleer de op...

Отзывы: