Specifications

Power: 275

 watts rms into 4 ohms from 30Hz to 15KHz at no more

than 1.5% total harmonic distortion (can be re-connected
internally for 8 or 16 ohm loads).

Sensitivity: 1.8 V rms to rated power
Small Signal Distortion: less than .2% at mid-band
Frequency Response: 20Hz to 20 kHz +0/-.25 dB
Hum and Noise: 108 dB below rated power output
Phase: phase correct
Input Impedance: 100 kOhms

Mechanical
Dimensions:
  18.75"D x 19"W x 7.13"H
Net Weight: 81 lb net

Fuses

The  LP260m  mono-block  power  amplifier power  transformer  is
protected  by  a  fuse  on  the  ac  power  line  (F5,  located  in  a
compartment in the ac line-cord receptacle mounted on the back of
the amplifier), and by four separate internal fuses on the secondary
circuits of the transformer (F1 – F4) located on the bottom of the pc
board.  A  failure  of  any  of  these  fuses  is  a  symptom  of  a  more
serious  problem,  and  a  competent  service  technician  should  be
consulted.  In  no  event  should  fuses  be  replaced  with  a  value  or
type different than that originally supplied. The correct fuse values
and types are:

F5:    5x20mm 10 amp T-type if configured for 100 or 120V:

  5x20mm 6.3 amp T-type if configured for 220 or 240V.

F4:    3AG type 4 amp, slow blow
F1, F2, and F3: ¼ amp, slow blow

The  output  stage  is  protected  by  a  plate  fuse  in  series  with  the
output tubes. This is a 5x20mm 2A fast-blow ceramic fuse, located
inside  the  chassis  in  fuse  holders  mounted  on  the  vertical  power
supply board.

Содержание LP260M

Страница 1: ...Conrad Johnson Owner s Manual LP260M Mono block Power Amplifier conrad johnson It just sounds right ...

Страница 2: ...ny years to come Accordingly circuit designs parts and materials for all conrad johnson products are selected with a view to maintaining optimal performance over the years Our reputation for producing among the industry s most reliable components is a natural consequence of this engineering approach Although operation of the LP260m mono block power amplifier is quite straightforward please take a ...

Страница 3: ... authorized conrad johnson dealer in the United States for use in the United States d Normal wear e Incidental or consequential damages are not covered under this warranty Some states do not allow the exclusion of incidental or consequential damages so this exclusion may not apply to you Obtaining Warranty Service To obtain warranty service the unit must be shipped along with evidence of purchase ...

Страница 4: ...The conrad johnson service department can also be reached by e mail at service conradjohnson com by phone at 703 698 8581 or by fax at 703 560 5360 Service If your conrad johnson audio component requires service repack it using the original box and packing material and ship to the Service Department address above Boxes and packing materials can be purchased through our service department if you no...

Страница 5: ...re has been taken in the design of the LP260m mono block power amplifier to minimize its susceptibility to radio frequency interference and other forms of EMI Choice of materials physical layout grounding practice and power supply design have all been specified with a view to reducing the impact of electromagnetic fields on the performance of this unit At the same time however our primary goal is ...

Страница 6: ...stem the two channels should be connected in correct relative phase This means that when the same signal is applied to both channels the right and left channels speaker diaphragms will move synchronously in and out together Terminals on speakers are usually coded one designated C ground or black the other designated or red In phase connection of the speakers can normally be achieved by taking care...

Страница 7: ...ono block power amplifier We highly recommend that you purchase replacement tube sets from conrad johnson design We anticipate tube life to accommodate two to three years of operation without degradation in normal use if the amplifier is switched off when not in use If it is left on at all times tube life can be exhausted in a matter of a few months The LP260m mono block power amplifier has been d...

Страница 8: ...should be performed whenever the amplifier s output tubes are replaced and after each six months of average use PLATE FUSE Your LP260m mono block power amplifier has been fitted with a plate supply fuse 5x20mm 2Amp fast blow ceramic that is installed to protect the amplifier circuitry in the event of output tube failure The fuse holder is physically located inside the amplifier in fuse clips on th...

Страница 9: ...by moving in they create a fall in pressure and the system is said to be phase inverting Each component in the stereo system either preserves the phase of the incoming signal and is said to be phase correct or inverts the phase and is said to be phase inverting It is unimportant whether an individual component is phase correct or phase inverting as long as the system as a whole is phase correct Th...

Страница 10: ...system dependent those that are top ranked on one system may be a poor choice for a different system Consult your conrad johnson dealer for recommendations for your specific system Performance Tip Warm up the LP260m mono block power amplifier before listening The sonic performance of the LP260m mono block power amplifier improves noticeably as the unit warms up The midrange becomes more lucid the ...

Страница 11: ...n a compartment in the ac line cord receptacle mounted on the back of the amplifier and by four separate internal fuses on the secondary circuits of the transformer F1 F4 located on the bottom of the pc board A failure of any of these fuses is a symptom of a more serious problem and a competent service technician should be consulted In no event should fuses be replaced with a value or type differe...

Отзывы: