Output 3 switches on
Output 3 switches off
Security check
The system was programmed (70#) to lock out the system for 30
seconds when the wrong code is entered 10 times.
Deliberately enter the wrong code 10 times, pressing the # key after
each code. After each # key press, the control unit should emit 5
beeps.
After this, your entire system is locked out for 30 seconds.
Entry of each code must take no longer than 10 sec-
onds between each key press or the system will return
to normal operation. If this occurs then the false entries
are ignored.
Door alarm
In the programming example (801#) your system was set to trigger
an alarm when the connection between „DOOR SENS“ and
„ground“ is interrupted. Open this connection (e.g. open the door)
without entering user code 1 and do not press the door opener in
the inner room.
Your base unit should now signal an alarm for 60 seconds.
The alarm can be ended preterm by entering user code 1.
68