17
• From the normal
operating mode
press and hold the control button for
5 seconds (LED lights up for 2 seconds and goes out, after 5 seconds
the LED lights up again)
• Release the button, the LED blinks in intervals, 1x each
• Press the button briefly 4x, the LED blinks in intervals, 5x each
• Press and hold the button for 2 seconds, (LED goes out after 2
seconds), then release the button, LED blinks in intervals, 1x each
• Select the desired command (see ‘3. Setting the command mode’) with
the control button.
3. Setting the ‘command mode’
After the switching flank has been selected, which switching command is
sent to the slave device is set here.
•
First
set the desired flank mode according to point 1 or 2, if not already
done!
• Then select the corresponding command mode according to the follow-
ing description:
X
X
X
X
X
No Command
This function means that when the ‘FS20 FMS’ is triggered,
no
switching command
will be transmitted:
f
LED blinks in intervals, 1x each
f
Press and hold the control button for 2 seconds, LED goes out,
release the button
f
Setting has been saved, the ‘FS20 FMS’ is in normal operating
mode