background image

 

 

Portable Metal Detectors By: 

 

 

M

O

D

E

L

 P

-4

0

0

0

 P

O

R

T

A

B

L

E

 M

E

T

A

L

 D

E

T

E

C

T

O

R

 

MODEL P-4000 

 

MANUAL 

PORTABLE 

Содержание P-4000

Страница 1: ...Portable Metal Detectors By MO D E L P 40 0 0 PO RT ABL E M E TAL D E TE C TO R MODEL P 4000 MANUAL PORTABLE...

Страница 2: ...e Two year warranty RENS Metal Detectors reserves the right to make changes in specifications and prices at any time without prior notice Spare Fuse 9525 SW Commerce Circle Wilsonville OR 97070 Phone...

Страница 3: ...ontact our Sales or Service Department at 800 367 9992 CONTENTS I ASSEMBLY II BATTERY CHECK III OPERATION OF UNIT Environment Indications of Metal Detection To Reset the Unit Daily Operation Setup Ope...

Страница 4: ...t coil lead to control box It is extremely important this is done correctly the female coil connector has a channel that must match up with the ridge on the male connector on the control box 3 Adjust...

Страница 5: ...attery charge If this is the case the battery should be topped off before use To check battery charge turn MODE switch to BATT position If the needle on the meter is high in the GREEN area battery is...

Страница 6: ...onds as it warms up and creates a magnetic field e The POWER lamp will switch from RED to GREEN and the sound will stop f The unit will be ready to operate in about 2 3 more seconds Under some extreme...

Страница 7: ...not only detect metal in the log or lumber but in the surrounding area as well DO NOT place logs on reinforced concrete pad or on ground surfaces containing buried metal such as pipes Using the P 400...

Страница 8: ...tself scan area again If the metal detector acts in the same manner a large metal object is being detected this is a normal reaction for the Metal Detector If unit does not settle down RESET by turnin...

Страница 9: ...table from 0 100db When using the unit in a noisy environment it may be advantageous to use the supplied earphones CAUTION To prevent ear damage when using earphones make sure VOLUME control is fully...

Страница 10: ...tion IV Specifications 1 Place search head close to the log surface and scan the entire length of the log as shown in diagram 2 Move to other side of the log and repeat step 1 3 Roll log over as requi...

Страница 11: ...position COMMON USER PROBLEM The MODE switch is sensitive to over torqueing The switch wiring configuration does not allow for extra room to move in either direction beyond the three designed spots O...

Страница 12: ...Adjustable in 3 positions POWER 17 5 Volt rechargeable Battery Pack Unit is protected with one 1 type 3 AG 3 10 Amp Slo Blo fuse located in battery compartment New fully charged Battery Pack will prov...

Страница 13: ...oint A Metal Type Distance 5D Nail finish 9 229mm 8d Nail 12 305mm 10d Nail 12 5 318mm 16d Nail 13 5 343mm 40d Nail 15 381mm 50d Nail 16 5 419mm 60d Nail 16 5 419mm 8 Spike 18 457mm Fence Staple 12 30...

Страница 14: ...ry is LOW When the unit is fully charged the LED light will become DIM B BATTERY PACK REPLACEMENT To replace the battery pack loosen the two screws securing the battery compartment access door located...

Страница 15: ......

Страница 16: ...Metal Detectors by Updated 2017 9525 SW Commerce Circle Wilsonville OR 97070 Phone 503 222 9992 800 367 9992 Fax 503 222 0073 Email RENS cnxsind com www cnxsind com...

Отзывы: