Connexus P-4000 Скачать руководство пользователя страница 8

 

~ 5 ~ 

 

Portable Metal Detectors By: 

INDICATIONS OF METAL DETECTION 

A.  If metal is being detected a sound will be heard 

– a small piece 

of metal will produce a small movement of the needle and a 
short chirp of sound. 
 

B.  Detection of a large or particularly dense metal object may be 

indicated  by  the  power  indicator  light  turning 

RED

,  meter 

needle  movement  to  the 

FAR  RIGHT

  and  a 

CONSTANT 

ALARM

 sound. 

  

 
HOWEVER:

  

Check that this is not a “false” indication.  Turn 

unit away from scanning area.  If unit settles down and resets 
itself, scan area again.  If the metal detector acts in the same 
manner,  a  large  metal  object  is  being  detected 

–  this  is  a 

normal reaction for the Metal Detector.  If unit does not settle 
down, 

RESET

 by turning unit off and going through start up 

procedures as stated previously. 

 

 

TO RESET THE UNIT 

To 

RESET

, turn 

MODE

 switch to 

OFF

, wait 1 to 2 seconds, then 

turn 

MODE

 switch to 

RUN

 

NOTE:

    If  the  detector  is  set on  a  metal  floor  or  near  any  other 

large piece of metal for a time while the system is in 

RUN

 mode, it 

will be necessary to perform a 

RESET

 action to remove the large 

error voltage that develops.  If a 

RESET

 is not performed it will take 

upwards  of  two  minutes  for  the  unit  to  restore  itself  to  proper 
operation. 

Содержание P-4000

Страница 1: ...Portable Metal Detectors By MO D E L P 40 0 0 PO RT ABL E M E TAL D E TE C TO R MODEL P 4000 MANUAL PORTABLE...

Страница 2: ...e Two year warranty RENS Metal Detectors reserves the right to make changes in specifications and prices at any time without prior notice Spare Fuse 9525 SW Commerce Circle Wilsonville OR 97070 Phone...

Страница 3: ...ontact our Sales or Service Department at 800 367 9992 CONTENTS I ASSEMBLY II BATTERY CHECK III OPERATION OF UNIT Environment Indications of Metal Detection To Reset the Unit Daily Operation Setup Ope...

Страница 4: ...t coil lead to control box It is extremely important this is done correctly the female coil connector has a channel that must match up with the ridge on the male connector on the control box 3 Adjust...

Страница 5: ...attery charge If this is the case the battery should be topped off before use To check battery charge turn MODE switch to BATT position If the needle on the meter is high in the GREEN area battery is...

Страница 6: ...onds as it warms up and creates a magnetic field e The POWER lamp will switch from RED to GREEN and the sound will stop f The unit will be ready to operate in about 2 3 more seconds Under some extreme...

Страница 7: ...not only detect metal in the log or lumber but in the surrounding area as well DO NOT place logs on reinforced concrete pad or on ground surfaces containing buried metal such as pipes Using the P 400...

Страница 8: ...tself scan area again If the metal detector acts in the same manner a large metal object is being detected this is a normal reaction for the Metal Detector If unit does not settle down RESET by turnin...

Страница 9: ...table from 0 100db When using the unit in a noisy environment it may be advantageous to use the supplied earphones CAUTION To prevent ear damage when using earphones make sure VOLUME control is fully...

Страница 10: ...tion IV Specifications 1 Place search head close to the log surface and scan the entire length of the log as shown in diagram 2 Move to other side of the log and repeat step 1 3 Roll log over as requi...

Страница 11: ...position COMMON USER PROBLEM The MODE switch is sensitive to over torqueing The switch wiring configuration does not allow for extra room to move in either direction beyond the three designed spots O...

Страница 12: ...Adjustable in 3 positions POWER 17 5 Volt rechargeable Battery Pack Unit is protected with one 1 type 3 AG 3 10 Amp Slo Blo fuse located in battery compartment New fully charged Battery Pack will prov...

Страница 13: ...oint A Metal Type Distance 5D Nail finish 9 229mm 8d Nail 12 305mm 10d Nail 12 5 318mm 16d Nail 13 5 343mm 40d Nail 15 381mm 50d Nail 16 5 419mm 60d Nail 16 5 419mm 8 Spike 18 457mm Fence Staple 12 30...

Страница 14: ...ry is LOW When the unit is fully charged the LED light will become DIM B BATTERY PACK REPLACEMENT To replace the battery pack loosen the two screws securing the battery compartment access door located...

Страница 15: ......

Страница 16: ...Metal Detectors by Updated 2017 9525 SW Commerce Circle Wilsonville OR 97070 Phone 503 222 9992 800 367 9992 Fax 503 222 0073 Email RENS cnxsind com www cnxsind com...

Отзывы: