background image

 

ES-U-1001-R10(R100) Premier Gold USB-RS232 Adapter cable Data Sheet

  

Version 1.1 

 

 

 

Document Reference No.: CP_000057  Clearance No.: CP#047 

 

 

 

 Copyright © Connective Peripherals Pte Ltd 

 

11

 

 

Windows Update shown on Windows XP 

You must have an active Internet connection and the Windows Update Service enabled. 

1)

 

Connect the ES-U-1001-R10 to your USB Host or Hub.   

2)

 

The “Found New Hardware” Wizard will appear.  The first dialog should ask whether it is 

acceptable to use the Windows Update Service to find the device driver.   

 

 

Figure 3-3 Found New Hardware Wizard 

3)

 

Select one of the “Yes” choices and click “Next”. 

4)

 

The following screen appears: 

 

Figure 3-4 Automatic Install 

5)

 

Wait while the driver is found, downloaded, and installed.  This step may take a couple minutes 
depending on the Internet speed. 

6)

 

After the files are found and installed, click “Finish” to complete the installation. 

 

Figure 3-5 Complete Hardware Installation 

Содержание ES-U-1001-R10

Страница 1: ...edical appliance device or system in which the failure of the product might reasonably be expected to result in personal injury This document provides preliminary information that may be subject to change without notice No freedom to use patents or other intellectual property rights is implied by the publication of this document Connective Peripherals Pte Ltd 178 Paya Lebar Road 07 03 Singapore 40...

Страница 2: ...s 7 1 7 Ordering Information 7 2 FT232R Key features 8 2 1 Integrated EEPROM 8 2 2 Pre programmed EEPROM 8 2 3 Lower Operating and Suspend Current 8 2 4 Low USB Bandwidth Consumption 8 2 5 UART Pin Signal Inversion 8 2 6 FTDIChip ID 8 2 7 Improved EMI Performance 8 2 8 Programmable Receive Buffer Timeout 9 2 9 Baud Rates 9 3 Installation 10 3 1 RS232 Connection Pin Out 10 3 2 Device Driver Install...

Страница 3: ...echanical Dimensions 17 7 Physical Environment Details 22 7 1 Operating Temperature 22 8 Environmental Approvals Declarations 23 8 1 EMI Compatibility 23 8 2 Safety 23 8 3 Environmental 23 8 4 Reliability 23 9 Troubleshooting 24 9 1 Hardware 24 9 2 Device Driver 24 9 3 Technical Support 25 10 Contact Information 26 Appendix A List of Figures and Tables 27 List of Figures 27 List of Tables 27 Appen...

Страница 4: ...t installations in industrial commercial and retail locations The Cable incorporates a standard USB A device connector for connection to an upstream host or hub port RS232 level signals including modem handshake signals are available on an industry standard DE 9P connector The maximum RS232 level data rate is 1MBaud The ES U 1001 R10 adapter cable requires USB device drivers available free from th...

Страница 5: ...arious 3rd Party Drivers are also available for various other operating systems see the Connective Peripherals website for details 1 4 Block Diagram FTDI FT232R USB Serial Bridge RS232 Level Shifter USB A Connector RS232 DE 9P Connector Cable 10cm or 100 cm Figure 1 1 Block diagram 1 4 1 Block description USB A Connector This connector provides the interface for connection to a USB Host or Hub por...

Страница 6: ...onnection reliability Integral 10cm ES U 1001 R10 or 100cm ES U 1001 R100 USB cable with moulded strain relief Quality 4 layer PCB design Easy plug play installation and RS 232 device connection Works with USB 1 1 2 0 Host and Hub ports Industry Standard FTDI chip set device drivers for maximum compatibility Microsoft Windows WHQL certified Mac OS X Linux and Windows CE device drivers Installs as ...

Страница 7: ... 2 0 Full Speed RS232 Interface Standard Windows baud rates 300bps to 921 6Kbps Custom baud rates 300bps to 1Mbps through baud rate aliasing See Application Note Configuring FT232R FT2232 and FT232BM Baud Rates Table 1 1 Performance Figures 1 7 Ordering Information Part Number Description ES U 1001 R10 Premier Gold USB RS232 Adapter Cable 10cm cable ES U 1001 R100 Premier Gold USB RS232 Adapter Ca...

Страница 8: ... 15mA and the suspend current has been reduced to around 70μA This allows greater margin for peripheral designs to meet the USB suspend current limit of 500μA 2 4 Low USB Bandwidth Consumption The operation of the USB interface to the FT232R has been designed to use as little as possible of the total USB bandwidth available from the USB host controller 2 5 UART Pin Signal Inversion The sense of ea...

Страница 9: ... non standard baud rates from 300 Baud up to 3 Mbaud Achievable non standard baud rates are calculated as follows Baud Rate 3000000 n x Where n can be any integer between 2 and 16 384 214 and x can be a sub integer of the value 0 0 125 0 25 0 375 0 5 0 625 0 75 or 0 875 When n 1 x 0 i e baud rate divisors with values between 1 and 2 are not possible This gives achievable baud rates in the range 18...

Страница 10: ... ES U 1001 R10 adaptor drivers are available for download from https www connectiveperipherals com 3 2 1 Microsoft Windows With the device drivers being Windows Hardware Quality Labs WHQL certified they are also available through download directly from the Microsoft Windows Update service This is the best choice when connecting the ES U 1001 R10 to a computer running Windows Vista Additional insta...

Страница 11: ...he Found New Hardware Wizard will appear The first dialog should ask whether it is acceptable to use the Windows Update Service to find the device driver Figure 3 3 Found New Hardware Wizard 3 Select one of the Yes choices and click Next 4 The following screen appears Figure 3 4 Automatic Install 5 Wait while the driver is found downloaded and installed This step may take a couple minutes dependin...

Страница 12: ...e Ready COM Port Assignment Next to determine which COM port has been assigned open the Windows Device Manager from the System Control Panel Figure 3 7 Device Manager Click on the Plus sign next to the Ports tree to list the available COM port You will see Connective Peripherals USB COM Port followed by a COMn assignment In the figure below the ES U 1001 R10 is assigned to COM3 Figure 3 8 COM Port...

Страница 13: ...Version 1 1 Document Reference No CP_000057 Clearance No CP 047 Copyright Connective Peripherals Pte Ltd 13 Figure 3 9 Access COM Port Properties Next click on the Port Settings tab Figure 3 10 Settings Tab Then click on the Advanced button Figure 3 11 Advanced Options ...

Страница 14: ...e upper left Clicking on the drop down list will display the available port numbers Select one that is not in use and click OK on each dialog box to activate the selection Windows will remember this COM port number 3 2 2 Mac OS X Linux Windows CE Device drivers and installation guides for Mac OS X Linux and Windows CE are available for download on the Connective Peripherals web site Follow the res...

Страница 15: ...itive polarity 4 Ground GND USB signal ground Shield Case Ground Drain typically connected to the host PC case Table 3 1 USB A Receptacle Pin Out 4 1 2 RS232 The RS232 port is configured as Data Terminal Equipment DTE with a 9 contact D Sub Pin connector Pin assignments are according to TIA EIA 574 which formally defines the assignments for a COM port found on many personal computers Pin Number Pi...

Страница 16: ...Units Conditions USB_VCC Input Power Voltage 4 25 5 0 5 25 V Present when USB cable is attached and USB Host or Hub powered Icc USB current 30 50 mA Table 5 1 USB Electrical Details 5 2 RS232 Parameter Description Minimum Typical Maximum Units Conditions Vtrans Transmitter output voltage swing 5 V RL 3KΩ Vrec Receiver input voltage range 2 4 25 V Input resistance 3KΩ to 7KΩ ESD HBM 15 KV RS 232 In...

Страница 17: ...Gold USB RS232 Adapter cable Data Sheet Version 1 1 Document Reference No CP_000057 Clearance No CP 047 Copyright Connective Peripherals Pte Ltd 17 6 Mechanical Details 6 1 Module Mechanical Dimensions Figure 6 1 Cable Dimensions ...

Страница 18: ... U 1001 R10 R100 Premier Gold USB RS232 Adapter cable Data Sheet Version 1 1 Document Reference No CP_000057 Clearance No CP 047 Copyright Connective Peripherals Pte Ltd 18 Figure 6 2 Case top Dimensions ...

Страница 19: ... U 1001 R10 R100 Premier Gold USB RS232 Adapter cable Data Sheet Version 1 1 Document Reference No CP_000057 Clearance No CP 047 Copyright Connective Peripherals Pte Ltd 19 Figure 6 3 Case Base Dimensions ...

Страница 20: ...ES U 1001 R10 R100 Premier Gold USB RS232 Adapter cable Data Sheet Version 1 1 Document Reference No CP_000057 Clearance No CP 047 Copyright Connective Peripherals Pte Ltd 20 Figure 6 4 Cap Dimensions ...

Страница 21: ...ES U 1001 R10 R100 Premier Gold USB RS232 Adapter cable Data Sheet Version 1 1 Document Reference No CP_000057 Clearance No CP 047 Copyright Connective Peripherals Pte Ltd 21 Figure 6 5 Lens Dimensions ...

Страница 22: ...ce No CP_000057 Clearance No CP 047 Copyright Connective Peripherals Pte Ltd 22 7 Physical Environment Details 7 1 Operating Temperature Parameter Description Minimum Typical Maximum Units Conditions T Operating Temperature Range 20 80 o C 5 to 95 RH non condensing Table 7 1 Operating Temperature ...

Страница 23: ...ay cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or ...

Страница 24: ... default settings of the device driver assume typical data transfers of hundreds to thousands or more bytes at a given time Some applications such as a GPS device only send data in short packets often only a few bytes If this is the case it may be necessary to adjust the driver s buffer size and or latency timer to smaller values These values can be adjusted through the advanced driver options as ...

Страница 25: ...n 1 1 Document Reference No CP_000057 Clearance No CP 047 Copyright Connective Peripherals Pte Ltd 25 9 3 Technical Support Technical support may be obtained from your nearest Connective Peripherals Office support connectiveperipherals com https www connectiveperipherals com ...

Страница 26: ...ls Pte Ltd 26 10 Contact Information Global Headquarters Singapore Connective Peripherals Pte Ltd 178 Paya Lebar Road 07 03 Singapore 409030 Tel 65 67430980 Fax 65 68416071 E Mail Sales sales connectiveperipherals com E Mail Support support connectiveperipherals com Web Site URL http www connectiveperipherals com Web Shop URL http www connectiveperipherals com ...

Страница 27: ...allation 11 Figure 3 6 Hardware Ready 12 Figure 3 7 Device Manager 12 Figure 3 8 COM Port Assignment 12 Figure 3 9 Access COM Port Properties 13 Figure 3 10 Settings Tab 13 Figure 3 11 Advanced Options 13 Figure 5 1 Cable Dimensions 17 Figure 5 2 Case top Dimensions 18 Figure 5 3 Case Base Dimensions 19 Figure 5 4 Cap Dimensions 20 Figure 5 5 Lens Dimensions 21 List of Tables Table 1 1 Performance...

Страница 28: ...47 Copyright Connective Peripherals Pte Ltd 28 Appendix B Revision History Revision Changes Date 1 0 Initial release 2009 08 04 1 1 Re branding to reflect the migration of the product from EasySync to Connective Peripherals name logo change copyright changed contact information Changed all internal hyperlinks changed 2019 03 28 ...

Страница 29: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Connective Peripherals ES U 1001 R100 ES U 1001 R10 ...

Отзывы: