background image

15 

 
 
 
 
 

3.1 LED Definitions 

LED 

Definition 

Color 

Operation 

P1 

Power 

Off 

Device is powered down.   

Green 

Device is powered on. 

P2 

Power 

Off 

Device is powered down.   

Green 

Device is powered on. 

STATUS 

System 

Status 

Orange 

System is booting up. 

Green 

System is working normally. 

Green 

Blinking 

When a USB is inserted, the Status 
LED indicator will blink 3 times in 
green. 
When upgrade procedure is 
completed, the Status LED indicator 
will blink 3 times in green. 

Orange 

Blinking 

When the system is set back to 
default factory setting, the Status LED 
indicator will blink 3 times in orange. 
When the system is restarted, the 
Status LED indicator will blink once in 
orange. 
System is undergoing upgrading 
procedure. 

ALM 

Alarm 

Off 

Power supplies link up. 

Orange 

One of power supplies links down. 

RM 

Role 

Off 

The role of switch is slave. 

Green 

The role of switch is master. 

Function 

Off 

Ring Detection is disabled. 

Green 

Ring Detection is enabled. 

Orange 

Blinking 

Local Port is link down in a Ring 
topology. 

Green 

Blinking 

Remote Port is link down in a Ring 
topology. 

LINK/ACT   

1~10 

Port Status 

Off 

Port link is down 

Orange 

Link is up and works at 10/100Mbps. 

Orange 

Blinking 

Receiving and transmitting data. 

Green 

Link is up and works at 1000Mbps. 

Green 

Blinking 

Receiving and transmitting data. 

 

Содержание IES-3110

Страница 1: ...IES 3110 Managed Industrial Gigabit Ethernet Switch User s Guide Version 0 90 ...

Страница 2: ...ption which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult your local distribut...

Страница 3: ...3 Revision History Version Date Description 0 90 20161007 First release 0 90 20170109 Remove Bluetooth ...

Страница 4: ...ge Contents 9 2 3 Installing the Managed Industrial Gigabit Ethernet Switch 10 2 4 Powering the Managed Industrial Gigabit Ethernet Switch 12 2 5 Connecting the switch to Network 14 3 OPERATION 14 3 1 LED Definitions 15 4 MAINTENANCE 16 4 1 Fault Identification 16 4 2 Hardware Replacement Procedures 16 4 3 Firmware and Configuration Upgrade 17 ...

Страница 5: ...sers can prevent network disconnection from unexpected power outage By employing store and forward switching mechanism the Switch provides low latency and faster data transmission Moreover it also supports more advanced ethernet management functions such as QoS and VLAN Users can configure the required settings of the Switch and monitor its real time operational status via Command Line Interface C...

Страница 6: ...K Bytes MAC Address Table 16K Non Blocking Switching Fabric 20Gbps VLAN ID 4K 1 Digital Output Alarm Relay Switch Features IEEE802 1q Tag Based VLAN IGMP Snooping v1 v2 QoS Based on P bit VLAN Broadcast Storm Control Port Mirroring Port Trunking Loop Detection Management Telnet CLI SNMP v1 v2c DHCP Client FTP HTTP TFTP USB Firmware Upgrade Dual Image SNTP SSHv2 Eventlog Syslog ...

Страница 7: ...X Multi mode fiber module 2km Single mode fiber module 1000BASE SX Multi mode fiber module 550m 1000BASE LX Single mode fiber module 10km 1000BASE LH Single mode fiber module 30km 50km 1000BASE ZX Single mode fiber module 80km Mini GBIC SFP Transceiver for 1000BASE SX Multi mode fiber module 550m 1000BASE LX Single mode fiber module 10km 1000BASE LH Single mode fiber module 30km 50km 1000BASE ZX S...

Страница 8: ...chapter 3 1 E 100 1000Mbps SFP port s F 10 100 1000Mbps RJ 45 port s Rear Panel Figure 4 Rear Panel G Din Rail metal spring for more information please refer to chapter 2 3 Top Panel Figure 5 Top Panel H Ground screw for more information please refer to chapter 2 3 I Terminal blocks for more information please refer to chapter 2 4 H I G ...

Страница 9: ... maximum possible current in each power wire and common wire If the current goes above the maximum ratings the wiring could overheat causing serious damage to your equipment Be sure to read and follow important guidelines as below Do not run signal or communications wiring and power wiring through the same wire conduit Wires with different signal characteristics should be routed separately to avoi...

Страница 10: ...P 1 Insert the top of the DIN Rail into the slot just below the metal spring STEP 2 The DIN Rail attachment unit will be snapped into place as shown Wall Mount Optional Use a wall mount with two screws to install the Managed Industrial Gigabit Ethernet Switch on the wall by a screwdriver The Managed Industrial Gigabit Ethernet Switch is able to be installed in either vertical or horizontal directi...

Страница 11: ...d Industrial Gigabit Ethernet Switch in horizontal direction Grounding the Managed Industrial Gigabit Ethernet Switch Grounding helps to limit the effects of noise due to electromagnetic interference EMI Be sure to install the ground connection from the ground screw to the grounding surface before connecting devices ...

Страница 12: ...at network cables and power cables are securely connected ATTENTION Before connecting the Managed Industrial Gigabit Ethernet Switch to the DC power inputs make sure the DC power source voltage is stable Wiring the terminal blocks P1 and P2 power supply are two pairs of contacts on the terminal block for power redundancy purpose The redundant power supply will take over seamlessly when one power s...

Страница 13: ...evices such as speakers or LEDs to alert users when the redundant power or a port link is disconnected The right contact is normal closed the left contact is normal open and the middle contact is com shared by normal open and normal closed Tighten the wire clamping screws to fix alarm device wires by using a flat head screwdriver P2 P1 P1 P2 Relay Wire clamping screws Wire clamping screws ...

Страница 14: ...rts can be inserted by 10 100 1000Base T cables connecting to the end devices The fiber port s can accept any kind of connector with proper SFP transceiver mini GBIC 3 OPERATION The Managed Industrial Gigabit Ethernet Switch is Plug Play Real time operational status can be monitored through a set of LED indicators located on the front panel A built in management module provides users with flexible...

Страница 15: ... indicator will blink 3 times in orange When the system is restarted the Status LED indicator will blink once in orange System is undergoing upgrading procedure ALM Alarm Off Power supplies link up Orange One of power supplies links down RM Role Off The role of switch is slave Green The role of switch is master R Function Off Ring Detection is disabled Green Ring Detection is enabled Orange Blinki...

Страница 16: ... Power connection Reset power When certain network link fails to function Locate the port of the switch Check Port Link Status LED Check cable connection between the port and the connected device Reset power Remote Check Users may check the Managed Industrial Gigabit Ethernet Switch through SNMP manager remotely For detailed procedures please refer to the Network Management User s Manual 4 2 Hardw...

Страница 17: ...ration can also be upgraded automatically via USB host Allows the network administrator for provisioning a device by just powering on and inserting disk Automatically upgrade firmware and or configuration when plug in an USB flash disk or hard disk USB support Flash disk or hard disk USB mass storage with partition Logic unit number LUN File system FAT12 FAT16 FAT32 NTFS3 1 read only and before Au...

Страница 18: ...e is not authorized wrong admin password or unauthorized The file is too big 16MB Firmware version current firmware version Configuration upgrade process would be skipped if The configuration file is not authorized wrong admin password or unauthorized Configuration current configuration Firmware Upgrade Configuration Upgrade Upgrade Complete ...

Отзывы: