Connecticut Electric EmerGen L14-20R Скачать руководство пользователя страница 1

 

Your new EmerGen Switch will provide you with a way to safely utilize 

your generator power through your existing electrical wiring during a power 
outage. You’ll install your switch next to your home’s electrical panel load
center and then you’ll connect circuit breaker wires to the transfer switch’s 
circuits. Once you power up your portable generator, you will manually turn on 
each switch and that generator energy is transferred  as electrical power and 

goes through the house circuits you have previously chosen. 

Your EmerGen Switch is easy for a licensed electrician or qualified

professional to install, safe for a homeowner to operate, and will work with
120/240V single phase AC generators, factory equipped with NEMA type
receptacles L14-20R

Your EmerGen Switch will not permit connection to both utility and generator
power at the same time. 

Wiring to the Load Center 

Page 4

Installing 240 volt (2 pole) Circuits 

Page 5

Completing the Installation 

Page 6

Operation / Test Procedure 
Load Management 

Page 7

Table of  Contents 

Trouble Shooting 

Page 8

Installation Instructions 

Page 3

Safety Information 
Installation Preparation 

Page 2

Congratulations !

On the purchase of your new EmerGen Switch

®

, another

Gould

premium quality product.

MANUAL TRANSFER SWITCH

Содержание EmerGen L14-20R

Страница 1: ...en Switch is easy for a licensed electrician or qualified professional to install safe for a homeowner to operate and will work with 120 240V single phase AC generators factory equipped with NEMA type receptacles L14 20R Your EmerGen Switch will not permit connection to both utility and generator power at the same time Wiring to the Load Center Page 4 Installing 240 volt 2 pole Circuits Page 5 Com...

Страница 2: ...plug the power cord set into your generator and into the EmerGen Switch before starting the generator and always shut the generator down before detaching the power cord set 3 Do not overload your generator or its circuit breakers will trip Using the EmerGen Switch s built in watt meters you can balance the loads to avoid impeding your generator s performance INSTALLATION PREPARATION 1 Decide which...

Страница 3: ...is does not affect the wires on the line side of the main breaker they will remain live Remove the cover of the load center 3 Identify 3 4 knockout to remove 4 Insert the wires from the flex conduit up through the knockout take care not to nick or gouge the wires on the metal edge Tighten the locknut securely onto the load center The wires can hang freely 5 Without over manipulating the flex condu...

Страница 4: ...he red and black EmerGen Switch wires labeled A Using good workmanship route both of these wires close to the selected circuit breaker a The red EmerGen Switch A wire is trimmed stripped and installed into the circuit breaker securely tightening the breaker lug b The black EmerGen Switch A wire and the hot wire from the circuit breaker removed in step 1 are placed up the side of the load center to...

Страница 5: ...de of the 2 pole circuit breaker b The black EmerGen Switch C wire and one of the hot wires from the circuit breaker are placed up the side of the load center Insert both wires into a yellow wire connector and twist tightly Push the wires back into the wiring compartment of the load center c The red EmerGen Switch D wire is trimmed stripped and securely installed into the remaining side of the 2 p...

Страница 6: ... ground bar in the load center b Cut and strip the wire appropriately Insert the wire into the hole and tighten securely 3 Replace the load center cover All circuit breakers can now be turned on including the MAIN circuit breaker 4 All EmerGen switches should be in the Line position The Off position is generally not used 5 Fill out the chart supplied with your EmerGen Switch describing each emerge...

Страница 7: ...rt your generator according to the manufacturer s instructions 5 At your EmerGen Switch move one circuit to the GEN position making a note of how much wattage is used on the watt meter While monitoring the load flip each circuit one at a time to the GEN position You do not need to go in order and you want to balance the loads so that both meters read approximately the same Do not switch on more lo...

Страница 8: ...are in OFF or LINE position 1 Move switches to GEN position 2 Generator circuit breaker has tripped 2 Reset circuit breaker 3 Poor connection or defective cord set 3 Check and repair 4 Connected device is bad 4 Select a different load or appliance that is in good condition 5 Fault in generator 5 Contact a qualified professional Appliances do not operate after utility power is restored 1 Switches a...

Отзывы: