3-42
Chapter 3: Software Installation - Windows NT
Echo
User's Manual, ver. 0.00
14.19.
Choose
EDIT
, then
ADD VALUE
, and enter in the
following values EXACTLY as below.
Value Name:
InterruptStatus
Data Type:
REG_DWORD
Value: 2C0
(Highlight
Hex
format Check Box)
Note:
1.
For our example of Base I/O address 280, the
Echo status port is at I/O address 2C0.
2.
The
Value
is the address of the status port
corresponding to I/O address range set on the
Echo adapter. All Echo ports on a single
board will have the same status port address,
so each key
Serial10000, Serial10001
up to
Serial1000n
will have the same value.
Once again choose
EDIT
, then
ADD VALUE
, and enter
in the following values EXACTLY as below.
Value name: PortIndex
Data Type: REG_DWORD
Value: 1
Note
:
Each key
Serial10000
,
Serial10001
up to
Serial1000n
will get a unique entry for its
Value
. You will enter 1
for Echo port one, 2 for port two, etc.
14.20.
Exit the Registry Editor and the system
automatically saves the new values.
15.
You can now reboot your system and your Windows NT
applications can access all the Echo serial ports.