Xtreme I/O Express ADC-DAC
Users Guide
Document: CTIM-00435
Revision: 0.08
Page 27 of 47
Connect Tech Inc. 800-426-8979 | 519-836-1291
Date: 2016-11-18
DAC8734 Internal Register Bank
CMD ADDR
DATA [15:0]
0x0
CONFIG CODE
This register must always be set to
0x3C
for normal operation. All other values
are undefined; do not load any values other than 0x3C into this location.
0x4
DAC0 CODE
This register contains the 16-bit code for the specific DAC output (0,1,2 or 3). Bit-
15=MSB, Bit-0=LSB.
CODE Formats:
For UNIPOLAR Mode = Straight Binary
For BIPOLAR Mode = Two’s Complement
0x5
DAC1 CODE
Same as DAC0 CODE
0x6
DAC2 CODE
Same as DAC0 CODE
0x7
DAC3 CODE
Same as DAC0 CODE
0x8
DAC0 ZERO CODE
0x9
DAC1 ZERO CODE
0xA
DAC2 ZERO CODE
0xB
DAC3 ZERO CODE
0xC
DAC0 GAIN CODE
0xD
DAC1 GAIN CODE
0xE
DAC2 GAIN CODE
0xF
DAC3 GAIN CODE