![Connect Tech Blue Heat/Net Sync Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/connect-tech/blue-heat-net-sync/blue-heat-net-sync_user-manual_2652848027.webp)
Connect Tech Blue Heat/Net Sync User Manual
Revision 0.03
27
password=
This sets the password phrase, which is used to gain access to the SCM and
WCM modes of configuring the Blue Heat/Net. The default is “password”.
prompt=
This setting controls whether a password prompt (and other password entry
status information) is presented to the terminal. This prompting is helpful for
new users of the product but may present a problem when other devices are
connected to the serial port.
yes
enables the password prompting (default)
no
disables the password prompting
file=
This sets the file name used as a default when using the
flldr
command.
It can be any sequence of characters up to 128 characters in length. (The default
is “BHNloader_vvv.gz”, where vvv is the current version number of the
“Loader”).
exit
Syntax:
exit [-nosave] [-no_reset][-login]
Description:
This command is to exit the SCM and reboot the Blue Heat/Net Sync. If CDS
changes have been made a warning message is issued and the SCM will not exit.
Options:
-nosave
Exit without saving changes (abandon changes).
-no_reset
Exit SCM without rebooting, maintaining the changes to settings for this session
only. (Booting is continued after the SCM is exited.)
-login
Exit without saving changes, and restart the SCM login process.
help
Syntax:
help
Description:
Displays a brief list of all the commands.
Options:
There are no options for the help command. Please note that specific help for the
options of each command can be obtained by entering any command with a
single “?” argument. An example would be
net ?
info
Syntax:
info [-v]
Description: This command is used to show basic information about the Blue Heat/Net Sync
unit, like Serial Number and Version Numbers, and performs a confidence
(CRC and Decompression verification) test of the contents of the flash memory.
Options:
-v
This option disables the confidence tests.
net
Syntax:
net
[network= | net=]