Table 1: BlueHeat/Net Sync Power Connections and Current Specifications
BlueHeat/Net
Description
Connector plug
type
Connector
Polarity
Voltage
Current
4 Port DB25
Synchronous /
Asynchronous
models (Rev A)
Centre Positive
*
5VDC
875mA
Left Positive
*
5-28VDC
@5V=2500mA
@28V=450mA
4 Port DB25
Synchronous /
Asynchronous
models (Rev B)
Centre Positive
*
5-28VDC
@5V=2500mA
@28V=450mA
Left Positive
*
5-28VDC
@5V=2500mA
@28V=450mA
*
Note: The power input is protected by a series diode to prevent damage in the case of a reverse polarity
connection.
Table 2: Connector Properties
Type
Details
Part Number
Typical Wire
Gauge
Standard DC Barrel
2.1mmID / 5.5mmOD
Digi-Key: CP3-1000-ND, or
equivalent
18-24 AWG
Stranded
Locking Screw Terminal,
3.3mm pitch
MC Series
Phoenix PN: 1847055, or
equivalent
16-28 AWG
Stranded
Screw Terminal,
3.5mm pitch
MC Series
Phoenix PN: 1840366, or
equivalent
16-28 AWG
Stranded