3. Programming users
Programming the CP1000 is simple and easy to understand.
3.1 User positions
CP1000 has 200 positions, which can contain a code or a proximity tag. The positions
are divided as following:
User position
Function
1 - 100
Activates output 2 (the code in position 1 is
1234
- factory default).
101 - 150
Activates output 1.
151 - 190
Activates output 1 and 2.
191 - 200
Reserved for special functions.
3.2 Programming user codes
The Master code is used to program/change/delete the users. By default the Master
code is
4711
.
LED indication: No light:
○
Light:
●
Flash:
*
Clear buffer:
New users
(4711 - standard)
○
●
○
●
●
○
●
●
○
○
●
○
To program more users, continue for “Key in the user positions” or press
to leave the programming mode.
●
○ ○
Changing user codes
It’s the same procedure as programming new users, just overwrite the user positions.
#
Key in the
Master code
#
Key in the
user position
#
Key in the
user code
#
4