Installation (continued)

INSTALLING THE GRILLE

 

-

Squeeze the springs on the grille together, and insert the 
springs into the slots of the housing assembly . Firmly push 

the grille up against the ceiling. See figure 20.

Spring slot

Ceiling

Fig . 20

Operation

TURNING ON/OFF THE UNIT

 

-

This ventilation fan with light can be operated with an external 

ON/OFF switch or two-function wall control.

 

WARNING:

 

To reduce the risk of fire or electric 

shock, do not use this fan with any solid-state speed 

control device .

Care and Cleaning

WARNING:

 

Failure to maintain basic standards of care and cleaning of the ventilation fan incr

eases the risk of fire, electric shock, 

or injury to persons. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means 
to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a 
prominent warning device, such as a tag, to the service panel.

The ventilation fan should be cleaned regularly (internally and externally) to preserve its appearance and performance . Remove grille to 
clean interior of ventilation fan .

Do:

Do Not:

 

-

Use a dusting brush attachment to gently vacuum 
the exterior and interior of the ventilation fan to 
remove dust and debris .

 

-

Do not let plaster dust or any other construction 
residue enter the fan . During construction or 
renovation, cover the fan .

 

-

Combustible products used for cleaning such as 
acetone, alcohol, ether, or benzol are highly explosive 
and should never be used close to the fan .

Содержание Aria QBVS110

Страница 1: ...BIT VENTILADOR PARA CUARTO DE BA O ULTRASILENCIOSO Y ALTO FLUJO DE AIRE PLEASE READ AND SAVE THESE INSTRUCTIONS INSTALLER PLEASE LEAVE THIS GUIDE WITH THE HOME OWNER LISEZ ET CONSERVEZ CES INSTRUCTION...

Страница 2: ...ciation NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage elect...

Страница 3: ...ed by loss of use of this product costs incurred for labour or materials removal and installation of replacement units or any other incidental or consequential damages Costs relating to obtaining acce...

Страница 4: ...l Safety goggles Drywall saw Pry bar Wood screws Respiratory mask Cable clamp Flexible duct connector Duct adapter For best performance use 4 round metal ducting Other ducting is acceptable but may im...

Страница 5: ...roceed with the installation Report damage and or missing parts immediately to our customer service team at cs conglomkb com or 1 877 333 0098 Service available in English and French Monday Friday fro...

Страница 6: ...VS110 6 ENGLISH Pre Installation continued TYPICAL INSTALLATION Roof Cap Wall Cap Elbows Aluminum Foil Tape Power Cable Insulation Ventilation Fan Round or Flexible Duct Connector Not Included or Fig...

Страница 7: ...ate so it can be enlarged to fit the new fan if required Check to ensure the joist arrow indicated on the template is oriented correctly It should be pointing towards the ceiling joist Mark the center...

Страница 8: ...his ventilation fan Check with qualified electrician if you are not sure whether the ventilation fan is properly grounded 2 Failure to follow electrical requirements may result in a fire 3 A fuse in t...

Страница 9: ...n the junction box before installing this unit Touching circuitry inside the ventilation fan while it is energized will result in death or serious injury DANGER All electrical wiring must be properly...

Страница 10: ...he Fan to The Ceiling Joists Finished Ceilings section If this is a new installation and your ceiling is unfinished proceed to Securing the Fan to The Ceiling Joists Unfinished Ceilings section SECURI...

Страница 11: ...cure the housing to your ceiling joists both conventional and I joist Choose the method most appropriate to your ceiling construction as shown in figures 16 and 17 Joist Profiles Reinstall motor mount...

Страница 12: ...y to persons Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconne...

Страница 13: ...the fan has been secured properly Tighten into position if necessary Check that the motor is secured in place If not then tighten the motor in place Check that the fan is not damaged If so replace th...

Страница 14: ...ower W 30 Voltage Frenquency 120 VAC 60Hz Housing Dimensions 11 3 8 x 10 1 2 x 7 5 8 28 9 cm x 26 7 cm x 19 4 cm Grille Dimensions 13 x 13 3 4 33 cm x 34 9 cm Net Weight Kg 3 42 WIRING DIAGRAM Black B...

Страница 15: ...please contact our customer service team at cs conglomkb com or 1 877 333 0098 8 30 am 5 pm EST Monday Friday Identify the required part s and have the part number s ready A B C D E F G Part Descript...

Страница 16: ...conglomkb com service available in English and French Monday Friday from 8 30 am 5 pm EST service disponible en anglais et fran ais du lundi au vendredi 8h30 17h H N E servicio disponible en ingl s y...

Отзывы: