Installation (continued)

SECURING THE FAN TO THE CEILING JOIST  - 
UNFINISHED CEILINGS

DANGER:

 

Turn off the power circuit breaker or the power switch 

on the junction box before installing this unit . Touching circuitry 
inside the ventilation fan while it is energized will result in 
death or serious injury .

NOTE:

 

Ensure your fan is properly connected to the duct work and electrical 

supply cable (not powered) before proceeding.

 

-

Secure the ventilation fan to the ceiling joist in a 
desired location . This fan offers several convenient 
ways to secure the housing to your ceiling joists 

(both conventional and I-joist). Choose the method 

most appropriate to your ceiling construction as 

shown in figures 16 and 17.

Joist Profiles

 

-

Reinstall motor mounting assembly . Plug the motor into the 

receptacle. See figure 18.

 

-

Power the fan to make sure everything is in proper working 
order .

 

- Once you are satisfied with your installation, protect the bath 

fan motor from construction dust and debris with the supplied 

dust cover (D) until construction is completed. See figure 19. 
Do not install the dust cover in finished construction. Do not 

operate the fan with the dust cover in place as it will damage 
the motor .

NOTE:

 

Duct and electrical connections not shown for clarity.

F

F

F

F

G

G

F

F

F

F

Hanger 
channels

Ceiling 
opening

Joist

Ceiling 
opening

Joist

C

L

Dust cover (D)

Fig . 17

Fig . 19

Fig . 16

Fig . 18

Содержание Aria QBVS110

Страница 1: ...BIT VENTILADOR PARA CUARTO DE BA O ULTRASILENCIOSO Y ALTO FLUJO DE AIRE PLEASE READ AND SAVE THESE INSTRUCTIONS INSTALLER PLEASE LEAVE THIS GUIDE WITH THE HOME OWNER LISEZ ET CONSERVEZ CES INSTRUCTION...

Страница 2: ...ciation NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage elect...

Страница 3: ...ed by loss of use of this product costs incurred for labour or materials removal and installation of replacement units or any other incidental or consequential damages Costs relating to obtaining acce...

Страница 4: ...l Safety goggles Drywall saw Pry bar Wood screws Respiratory mask Cable clamp Flexible duct connector Duct adapter For best performance use 4 round metal ducting Other ducting is acceptable but may im...

Страница 5: ...roceed with the installation Report damage and or missing parts immediately to our customer service team at cs conglomkb com or 1 877 333 0098 Service available in English and French Monday Friday fro...

Страница 6: ...VS110 6 ENGLISH Pre Installation continued TYPICAL INSTALLATION Roof Cap Wall Cap Elbows Aluminum Foil Tape Power Cable Insulation Ventilation Fan Round or Flexible Duct Connector Not Included or Fig...

Страница 7: ...ate so it can be enlarged to fit the new fan if required Check to ensure the joist arrow indicated on the template is oriented correctly It should be pointing towards the ceiling joist Mark the center...

Страница 8: ...his ventilation fan Check with qualified electrician if you are not sure whether the ventilation fan is properly grounded 2 Failure to follow electrical requirements may result in a fire 3 A fuse in t...

Страница 9: ...n the junction box before installing this unit Touching circuitry inside the ventilation fan while it is energized will result in death or serious injury DANGER All electrical wiring must be properly...

Страница 10: ...he Fan to The Ceiling Joists Finished Ceilings section If this is a new installation and your ceiling is unfinished proceed to Securing the Fan to The Ceiling Joists Unfinished Ceilings section SECURI...

Страница 11: ...cure the housing to your ceiling joists both conventional and I joist Choose the method most appropriate to your ceiling construction as shown in figures 16 and 17 Joist Profiles Reinstall motor mount...

Страница 12: ...y to persons Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconne...

Страница 13: ...the fan has been secured properly Tighten into position if necessary Check that the motor is secured in place If not then tighten the motor in place Check that the fan is not damaged If so replace th...

Страница 14: ...ower W 30 Voltage Frenquency 120 VAC 60Hz Housing Dimensions 11 3 8 x 10 1 2 x 7 5 8 28 9 cm x 26 7 cm x 19 4 cm Grille Dimensions 13 x 13 3 4 33 cm x 34 9 cm Net Weight Kg 3 42 WIRING DIAGRAM Black B...