![Congatec conga-IA5 Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/congatec/conga-ia5/conga-ia5_user-manual_2652468041.webp)
Copyright
©
2017
congatec
AG
IA50m10
41/59
5.8.3
eDP Connector
The conga-IA5 provides an eDP connector (X29). In order to use it, change the "Active LFP Configuration" in the BIOS setup menu to "eDP".
Table 33 X29 Pinout Description
Pin
Signal
Pin
Signal
1
N.C
21
VCC_LCD
2
GND
22
N.C
3
eDP_TX3-
23
GND
4
24
GND
5
GND
25
GND
6
eDP_TX2-
26
GND
7
27
eDP_HPD
8
GND
28
GND
9
eDP_TX1-
29
GND
10
30
GND
11
GND
31
GND
12
eDP_TX0-
32
eDP_LVDS_BKLT_EN
13
33
eDP_LVDS_BKLT_CTRL
14
GND
34
N.C
15
35
N.C
16
eDP_AUX-
36
N.C
17
GND
37
BKLT_PWR
18
VCC_LCD
38
BKLT_PWR
19
VCC_LCD
39
BKLT_PWR
20
VCC_LCD
40
N.C
Connector Type
X29: 40 pins, 0.5mm pitch, (ACES 50203-04001-001)
Note
congatec offers cables and adapter for the eDP interface (see section 1.2.2 “Optional Accessories/Cables”). For more information, contact
the congatec technical solution department.
X29