Congatec conga-CEVAL Скачать руководство пользователя страница 25

Copyright 

© 

2012 

congatec 

AG 

 

      CEVA_c_m10 

 

      

25/47

4.1.4.4 

LPC Firmware Hubs

The conga-CEVAL offers the possibility to boot the COM Express™ CPU module with an external BIOS instead of the module’s onboard BIOS. 

This can be very useful when a customized BIOS is evaluated. 

Onboard the conga-CEVAL is a 32-lead PLCC socket for LPC firmware hub (FWH in socket S1). With the DIP switch M46, you can configure 

which firmware hub the COM Express™ CPU module should boot from. When the yellow LED D28 is lit, this indicates the module boots with 

the BIOS located on the FWH in socket S1. 

The table below shows the different DIP switch settings for M46 necessary to either boot from the carrier board FWH on the conga‑CEVAL or 
to boot from the onboard FWH on the COM Express™ CPU module.

DIP Switch M46

Configuration

Switch 1

Switch 2

BIOS Entry / SPI_CS0#

 OFF

OFF

Module FWH or SPI

OFF

ON

Carrier FWH

ON

OFF

Carrier SPI CS0#

ON

ON

Carrier SPI CS1#

4.1.5 

Universal Serial Bus (USB)

Pin

Signal

1

+5V

2

DATA‑

3

DATA+

4

GND

 

Note

The USB ports 4 and 5 found on the connector X50 are supplied by suspend power and can be used to test the function "wake-up via USB"

PLCC Socket

S1

D28

2

1

ON

DIP SWITCH

(M46)

USB Port 3

USB Port 2

USB Port 1

USB Port 0

X51

(front view)

USB Port 4

USB Port 5

X50

(front view)

8 7 6 5 4 3 2  1

Содержание conga-CEVAL

Страница 1: ...COM Express conga CEVAL Detailed description of the congatec COM Express Type 2 evaluation carrier board User s Guide Rev C x Revision 1 0...

Страница 2: ...Copyright 2012 congatec AG CEVA_c_m10 2 47 Revision History Revision Date yyyy mm dd Author Changes 1 0 2013 09 17 AEM Initial release...

Страница 3: ...guide In no event shall congatec AG be liable for any incidental consequential special or exemplary damages whether based on tort contract or otherwise arising out of or in connection with this user...

Страница 4: ...e conga CEVAL evaluation carrier board not the connector found on the conga CEVAL evaluation carrier board Link to connector layout diagram This link icon is located in the top left corner of each pag...

Страница 5: ...AG will pay for transporting the repaired or exchanged product to the customer Repaired replaced or exchanged product will be warranted for the repair warranty period in effect as of the date the repa...

Страница 6: ...o a collection of two PCI Express Lanes etc Also referred to as x1 x2 x4 or x16 link ExpressCard A PCMCIA standard built on the latest USB 2 0 and PCI Express buses USB Universal Serial Bus SATA Seria...

Страница 7: ...4 4 LPC Firmware Hubs 25 4 1 5 Universal Serial Bus USB 25 4 1 6 LAN 10 100 1000 26 4 1 7 Serial ATA 26 4 1 8 VGA 27 4 1 9 LVDS Flat Panel Interface 28 4 1 9 1 Flat Panel and Backlight Power Supply 2...

Страница 8: ...and optimized package which results in a more reliable product while simplifying system integration Most importantly COM Express applications are scalable which means once a product has been created t...

Страница 9: ...Copyright 2012 congatec AG CEVA_c_m10 9 47 Compact Basic and Extended Form Factor...

Страница 10: ...A TV Out LVDS PEG SDVO Type 6 A B C D Up to 24 1 4 1 8 4 3xDDI PEG VGA LVDS Type 10 A B Up to 4 1 2 1 8 0 1xDDI The conga CEVAL evaluation board uses the Type 2 pin out definition This pinout offers t...

Страница 11: ...Copyright 2012 congatec AG CEVA_c_m10 11 47 Dual 24 bit LVDS channels ExpressCards Analog VGA TV Out HDA AC 97 digital audio interface Gigabit Ethernet LPC interface 8 GPIO pins...

Страница 12: ...D28 X28 X25 X26 X21 Compact Flash Master Slave LED D25 M2 X70 Fan Power Config X63 PwrGood Config X11 X12 X7 M6 X72 X45 X44 M3 TEST PT TEST PT TEST PT TEST PT COMe PWROK M1 Backlight Power Config X67...

Страница 13: ...M1 is pressed The ATX power supply can also be used in AT mode In this case the module will start after the power switch on the power supply is turned on Jumper X6 Configuration 1 2 ATX Power supply...

Страница 14: ...ower Supply 3 3VDC 2 3 3V Power Supply 3 3VDC 14 12V Power Supply 12DC 3 GND Power Ground 15 GND Power Ground 4 5V Power Supply 5VDC 16 PS_ON Power Supply On active low Short this pin to GND to switch...

Страница 15: ...standby is present on the baseboard D3 Indicates that 5V is present on the baseboard D4 Indicates that 3 3V is present on the baseboard 3 2 2 PWR_OK Signal The COM Express specification defines the si...

Страница 16: ...bility to choose if the PS_ON signal should be controlled either by the SUS_S3 signal or SUS_S5 signal This is accomplished on earlier conga CEVAL revisions through the use of jumper X63 The conga CEV...

Страница 17: ...battery that supplies power to the RTC circuit of the COM Express CPU module The battery provides 3V of power The specified battery type is CR2032 Note To fulfill the requirements of the EN60950 the c...

Страница 18: ...F B14 SMB_DAT A69 PCIE_TX0 B69 PCIE_RX0 A15 SUS_S3 B15 SMB_ALERT A70 GND FIXED B70 GND FIXED A16 SATA0_TX B16 SATA1_TX A71 LVDS_A0 B71 LVDS_B0 A17 SATA0_TX B17 SATA1_TX A72 LVDS_A0 B72 LVDS_B0 A18 SUS...

Страница 19: ...SVD A49 EXCD0_CPPE B49 SYS_RESET A104 VCC_12V B104 VCC_12V A50 LPC_SERIRQ B50 CB_RESET A105 VCC_12V B105 VCC_12V A51 GND FIXED B51 GND FIXED A106 VCC_12V B106 VCC_12V A52 PCIE_TX5 B52 PCIE_RX5 A107 VC...

Страница 20: ...more the conga CEVAL includes an I C application implemented by a PCA9555 device from Philips a 16 bit I C I O port with interrupt This device provides 16 bits of general purpose parallel Input Output...

Страница 21: ...ack 1 Stereo Mode 5 1 Channel Mode Tip Line Input Left Rear Channel Output Left Ring Line Input Right Rear Channel Output Right Sleeve Ground Ground Stereo Jack 2 Stereo Mode 5 1 Channel Mode Tip Line...

Страница 22: ...fixed rate sample synchronization signal to the CODEC s 4 AC_RST HDA_ RST Reset output to AC 97 HDA CODEC active low 5 AC_SDIN0 2 HDA_ SDOUT0 2 Serial TDM data inputs from up to 3 CODECs SDIN2 is conn...

Страница 23: ...erfaces provided by this Super I O controller are available on connectors X28 X38 X54 and X55 Both Serial port COM1 and COM2 are based on RS232 standard For the pinout of the mouse keyboard COM1 COM2...

Страница 24: ...The LPC Super IO address can be selected with the DIP switch M53 DIP Switch M53 Configuration SW1 On Super I O Controller PnP reg 4Eh SW1 Off Super I O Controller PnP reg 2Eh default SW2 On No default...

Страница 25: ...ed on the FWH in socket S1 The table below shows the different DIP switch settings for M46 necessary to either boot from the carrier board FWH on the conga CEVAL or to boot from the onboard FWH on the...

Страница 26: ...100 SLED D31 LK1000 Connector Type 8 pin RJ45 plug 4 1 7 Serial ATA Pin Signal 1 GND 2 TX 3 TX 4 GND 5 RX 6 RX 7 GND The red LED D29 indicates activity on each SATA interface LAN X50 front view 8 7 6...

Страница 27: ...monitor can be connected using the X55 connector Pin Signal 1 RED 2 GREEN 3 BLUE 4 N C 5 GND 6 GND 7 GND 8 GND 9 DDC Power 10 GND 11 N C 12 DDC DAT 13 HSYNC 14 VSYNC 15 DDC CLK Connector Type VGA X55...

Страница 28: ...VDS Channel B differential pairs 23 GND Power Ground 24 LVDS_B1 LVDS Channel B differential pairs 25 LVDS_B1 LVDS Channel B differential pairs 26 GND Power Ground 27 LVDS_B2 LVDS Channel B differentia...

Страница 29: ...L_R 9 GND 10 GND Connector Type X2 10 pin 2 row 2 54 mm grid box header Jumper X66 Configuration 1 2 5V LCD Voltage default 2 3 3 3V LCD Voltage Jumper X8 Configuration 1 2 12V Backlight Voltage defau...

Страница 30: ...ls 1 10 found on the X2 connector X66 X67 and X69 represent jumpers X66 X67 and X69 found on the conga CEVAL The conga CEVAL carrier board is equipped with a Maxim MAX5362 device referred to in the di...

Страница 31: ...the conga CEVAL DIL 8 socket S2 Note Supported EEPROMs 24C02 24C04 and 24C16 at address A0h 4 1 10 PCI Express x1 Connectors The conga CEVAL is equipped with 4 x1 PCI Express Slots The tables below de...

Страница 32: ...T 2_S0 A17 PCIE_RX0 B17 PRSNT 2_S1 A17 PCIE_RX1 B18 GND A18 GND B18 GND A18 GND PCI Express Slot 2 Lane 3 Connector X45 PCI Express Slot 3 Lane 4 Connector X44 Pin Signal Pin Signal Pin Signal Pin Sig...

Страница 33: ...ort for up to two ExpressCard slots More information about the ExpressCard Standard can be found at http www expresscard org The following table lists the default pinout of the ExpressCard slot It uti...

Страница 34: ...andardized PCI Express Mini Card device to the carrier board without additional redesign cost The PCI Express Mini Card uses USB port 7 and PCI Express lane 5 by default The following table lists the...

Страница 35: ...n cases it is necessary to use this DIP switch For instance when dealing with some congatec COM Express modules that support onboard Gigabit Ethernet implemented with PCI Express lane 5 This means tha...

Страница 36: ...Chrominance Analog Signal C 2 Luminance Y S Video Luminance Analog Signal Y 3 GND C Analog Ground for Chrominance C 4 GND Y Analog Ground Luminance Y 5 GND Analog Ground 6 GND Analog Ground 7 Composi...

Страница 37: ...PEG_TX6 C18 PCI_GNT1 D18 IDE_RESET C73 SDVO_DATA D73 SVDO_CLK C19 PCI_REQ1 D19 PCI_GNT3 C74 PEG_RX7 D74 PEG_TX7 C20 PCI_GNT0 D20 PCI_REQ3 C75 PEG_RX7 D75 PEG_TX7 C21 GND FIXED D21 GND FIXED C76 GND D...

Страница 38: ...D103 GND C49 PCI_IRQA D49 PCI_M66EN C104 VCC_12V D104 VCC_12V C50 PCI_IRQB D50 PCI_CLK C105 VCC_12V D105 VCC_12V C51 GND FIXED D51 GND FIXED C106 VCC_12V D106 VCC_12V C52 PEG_RX0 D52 PEG_TX0 C107 VCC_...

Страница 39: ...DE_IOR 26 GND 7 IDE_D5 8 IDE_D10 27 IDE_RDY 28 CSEL 9 IDE_D4 10 IDE_D11 29 IDE_ACK 30 GND 11 IDE_D3 12 IDE_D12 31 IDE_INTRQ 32 N C 13 IDE_D2 14 IDE_D13 33 IDE_A1 34 CBLID_P 15 IDE_D1 16 IDE_D14 35 IDE...

Страница 40: ...id jumper The following table lists the pinout of the CompactFlash socket Pin Signal Pin Signal 1 GND 26 CD1 2 IDE_D3 27 IDE_D11 3 IDE_D4 28 IDE_D12 4 IDE_D5 29 IDE_D13 5 IDE_D6 30 IDE_D14 6 IDE_D7 31...

Страница 41: ...connector can be found in the congatec COM Express Design Guide PCI_IRQA PCI_IRQB PCI_IRQC PCI_IRQD PCI_AD20 PCI_AD21 PCI_AD22 PCI_AD23 Pin A26 Pin A6 Pin B7 Pin A7 Pin B8 Pin A6 Pin B7 Pin A7 Pin B8...

Страница 42: ...2 PC Speaker Beeper The board mounted speaker provides audible error code beep code information during POST The speaker M11 is connected to the COM Express module s SPEAKER signal The DIP Switch M50...

Страница 43: ...atec COM Express modules is available at www congatec com The DIP Switch M45 is used for port selection DIP Switch M45 Configuration SW1 On PCI POST default SW1 Off LPC POST SW2 On POST ADDR 80h 84h d...

Страница 44: ...This signal must receive two pulses per revolution in order to produce an accurate reading and therefore a two pulse per revolution fan is recommended 5 7 SMART Battery Management Module Connector X1...

Страница 45: ...n over temp situation 29 GPI3 30 PCI_M66EN Module input signal indicates whether an off module PCI device is capable of 66MHz operation 31 BATLOW Indicates that external battery is low 32 WAKE1 Genera...

Страница 46: ...Copyright 2012 congatec AG CEVA_c_m10 46 47 6 Mechanical Drawing conga CEVAL...

Страница 47: ...dio Specification Rev 1 0 http www intel com standards hdaudio LVDS Owner s Manual http www national com Extended Display Identification Data Standard Version 1 3 EDID http www vesa org Enhanced Displ...