Copyright
©
2012
congatec
AG
CEVA_c_m10
13/47
3
Specifications
3.1
Mechanical Dimensions
294.0 mm x 244.0mm
Height approx. 43mm
3.2
Power Supply
The conga‑CEVAL can be used with standard ATX (Connector X70) power supplies.
When using an ATX power supply, the COM Express™ module starts after the power‑on button M1 is pressed. The ATX power supply can also
be used in AT mode. In this case the module will start after the power switch on the power supply is turned on
Jumper X6
Configuration
1 ‑ 2
ATX Power supply mode (default)
2 ‑ 3
ATX Power supply runs in AT mode
Connector Type
X6: 2.54mm grid jumper.
The conga‑CEVAL can also be used with 12V DC power supply (connector M2 and M7).
Connector
Configuration
M7
Ground
M2
+12VDC (11,4 – 12,6V)
Connector Type
4mm diameter plug
1
2
3
Power Mode
Config
(X6)
Pwr On
(M1)
GND
(M7)
+12V
(M2)