![Congatec 050700 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/congatec/050700/050700_user-manual_2652481017.webp)
Copyright
©
2022
congatec
GmbH
TSTLm01
17/72
2.4.1
Electrical Characteristics
Power supply pins on the module’s connectors limit the amount of input power. The following table provides an overview of the limitations for
pinout Type 6 (dual connector, 440 pins).
Power Rail Module Pin
Current Capability
(Ampere)
Nominal
Input
(Volts)
Input
Range
(Volts)
Derated
Input
(Volts)
Max. Input Ripple
(10 Hz to 20 MHz)
(mV)
Max. Module Input
Power (w. derated input)
(Watts)
Assumed
Conversion
Efficiency
Max. Load
Power
(Watts)
VCC_12V
12
12
11.4-12.6
11.4
+/- 100
137
85%
116
VCC_5V-SBY
2
5
4.75-5.25
4.75
+/- 50
9
VCC_RTC
0.5
3
2.5-3.3
+/- 20
2.4.2
Rise Time
The input voltages shall rise from 10% of nominal to 90% of nominal at a minimum slope of 250 V/s. The smooth turn-on requires that, during
the 10% to 90% portion of the rise time, the slope of the turn-on waveform must be positive.
2.5
Power Consumption
The power consumption values were measured with the following setup:
•
conga-TS570 COM
•
modified congatec carrier board
•
conga-TS570 cooling solution
•
Microsoft Windows 10 (64 bit)
Note
The CPU was stressed to its maximum workload with the Intel
®
Thermal Analysis Tool