IF THE WATER PURIFIER IS NOT WORKING
INDICATION
FAULT CAUSE
REMEDIAL ACTION
Alarm indicating that calibration
has been commenced, but not
carried out correctly (probably
due to the tap having been
closed before 10 minutes had
elapsed).
•
Restart the water purifier by pulling out and
reconnecting the plug so that flushing is
performed. Recalibrate the water purifier
according to the section “Calibration”.
Alarm for fault in the water quality
meter.
•
Restart the water purifier by pulling out and
reconnecting the plug so that flushing is
performed. Wait for 2 hours then use the water
purifier as normal.
Low water flow
The membrane may have
become blocked.
•
Clean the water purifier in accordance with
“Cleaning/Descaling”.
The appliance
false starts (short
starts)
The water pressure between the
water purifier and e.g. tap, valve
or tank has dropped below the
water purifier’s starting pressure
level.
•
Check the connections.
•
Check that the ends of the water purified water
hose are flat, circular and with no burrs.
•
Check that taps and valves are watertight in their
closed position.
Unpleasant odour When the water purifier is
stationary (without power supply)
and there is microbiological
growth in the water,
the water can smell “bad”.
•
Try flushing the water purifier according to the
section “Flushing”.
•
Clean the water purifier in accordance with
“Disinfection”.
If the water purifier has experienced an emergency stop, it must be restarted by pulling out the plug, waiting
for at least one minute and then reconnecting the plug again. If problems remain with the water purifier after
having read and tried to implement remedial measures in accordance with the trouble-shooting table, contact
your dealer.
Service and spare parts
Use the trouble-shooting table to make sure that
you cannot remedy the fault yourself.
If you have been unable to get your water purifier
to work, despite implementing the measures
described in the checklist, it is time to call for
service. By going through your dealer, you will
receive service with genuine spare parts for your
water purifier.
Before calling for service, it is worth noting a few
details. Look at the data plate, see fig. A, which is
located on the rear of the appliance. All the
required information that the service department
needs to know about your water purifier can be
found here. You can record these details here:
TYPE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
MODEL: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PROD. NO.: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SER. NO.: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
A
15
Содержание RO 400C
Страница 3: ...PRODUCT DESCRIPTION 8 5 3 4 3 2 1 11 12 13 6 14 7 9 10 3 ...
Страница 101: ...APPENDIX 1 3 2 4 5 6 7 8 10 9 11 ...
Страница 102: ...102 ...
Страница 103: ...103 ...
Страница 104: ...04 01 AD 104 ...