1 Introduction

1.1 Short description

Conergy PH modules are solar modules for installation in photovoltaic systems.

1.2 About this manual

1.2.1 Subject of this manual

The subject of this manual is the installation and electrical connection of the Conergy PH module in a photovoltaic system. 
This manual applies to the following modules: Conergy PH 175-200M, Conergy PH 220-255P, Conergy PH 230-260M BL.

1.2.2 User group

The manual is intended to be used by the system owner and by qualified persons possessing technical skills and basic 
electrical, electronic and mechanical knowledge related to photovoltaic systems. Please retain this manual for future 
reference.

1.2.3 Symbols

Start of a step-by-step procedure with description of the goal of the procedure. Individually numbered steps 
follow, which may be interrupted by background information, illustrations, or warnings.

Background and additional information or the status of a procedure. Appears between the steps of a procedure, 
within the sequence/ course of a procedure.

Denotes a hazardous situation. Disregard of this instruction may lead to slight or moderate injury.

Denotes an extraordinarily hazardous situation. Disregard of this instruction may lead to serious, irreversible 
injury or death.

1.3 Standards and technical directives

Conergy PH modules comply with the following standard:
|  ULC/ORD-C1703-01 & UL 1703

1.4 Intended use

Conergy PH modules are designed for use in photovoltaic systems. Any other use is deemed to be not as intended. 
Intended use also includes compliance with the specifications stated in this installation manual. Conergy shall not be held 
liable for damages arising from a failure to observe and follow the installation manual, particularly the safety instructions, 
or from any improper use of the product.

2 Safety

2.1 Responsibilities of the owner/operator

Installing solar photovoltaic systems may require specialized skills and knowledge. The system operator has safety-related 

responsibilities, and must ensure that:

|  locally applicable standards and directives are complied with; 
|  the installation is performed by qualified persons; 
|  those commissioned to perform the work can evaluate their assigned tasks and recognize possible risks;
|  those commissioned to perform the work are familiar with the system components; 
|  the installation manual is available during the installation; 
|  the installation manual is an integral part of the product; 

Содержание PH 175-200M

Страница 1: ...Conergy PH Series Modules Solar module user manual ...

Страница 2: ...oderate injury Denotes an extraordinarily hazardous situation Disregard of this instruction may lead to serious irreversible injury or death 1 3 Standards and technical directives Conergy PH modules comply with the following standard ULC ORD C1703 01 UL 1703 1 4 Intended use Conergy PH modules are designed for use in photovoltaic systems Any other use is deemed to be not as intended Intended use a...

Страница 3: ...nd etc The modules have been evaluated by UL for mounting using the 4 provided mounting holes in the frame Make sure that no other system components will impair the mechanical or electrical function of the Conergy PH modules Do not drill holes in the module frame or in the glass surface and do not carry out any welding work on or near the Conergy PH modules Comply with the applicable occupational ...

Страница 4: ...4 A 1580 mm B 50 mm C 300 mm A 1652 mm B 50 mm C 300 mm Fig 3 1 Dimensions mm Conergy PH 175 200M Conergy PH 220 255P and Conergy PH 230 260M BL Variable clamping range ...

Страница 5: ...e 2 Insert four stainless steel bolts M6 through the holes 7x11 5mm in the frame For maximum security against strong winds and snow falls all six mounting holes should be used to secure the modules 3 Secure each bolt to the frame with 2 stainless steel washers a stainless steel spring washer or toothed lock washer and a stainless steel nut M6 4 To tighten a torque wrench is recommended to produce ...

Страница 6: ... is adequate protection against contact with live conductors Use only insulated tools 3 3 3 Parallel and series connection Modules of the same type can be connected in parallel or in series Modules or series strings of modules connected in parallel may require overcurrent protection in each series string The maximum series fuse ratings for Conergy PH modules are as follows PH 175 200M 10A PH 230 2...

Страница 7: ...ends that you carry out a visual inspection and a check of the mechanical and electrical connections for damage once a year Dirt on the modules reduces the output and the yield If the photovoltaic modules are installed with an inclination angle of more than15 they will generally be adequately cleaned by rain Prevent damage to the module surface by scratching or extreme differences in temperature U...

Страница 8: ...6A 29 16V 8 06A 240Wp 37 77V 8 59A 29 54V 8 13A 245Wp 37 98V 8 62A 29 92V 8 20A 250Wp 38 19V 8 65A 30 30V 8 27A 255Wp 38 40V 8 69A 30 68V 8 33A The electrical characteristics are within 10 percent of the indicated values of Isc Voc and Pmax under standard test conditions irradiance of100mW cm2 AM 1 5 spectrum and a cell temperature of 25 C 77 F Conergy PH 230 260M BL Maximum Power Pmax Open Circui...

Страница 9: ...G Y Conergy Global Headquarters Anckelmannsplatz 1 20537 Hamburg Germany Phone 49 0 40 27 142 1000 www conergy com Conergy US Headquarters 2460 West 26th Avenue Suite 280C Denver CO 80211 US Toll Free 888 396 6611 www conergy us Conergy Canada Headquarters 17815 111 Ave Edmonton AB T5S 2X3 Canada Toll Free 1 888 489 3701 In Canada www conergy ca ...

Отзывы: