background image

CGU 04i   DESCRIPTION 

39 

Parameter name 

Set value range  

Parameter description 

GPRS – enable 
duplicate registration 

YES/NO 

When the station is Local DNS server, then 
this parameter enable logging of the modem 

with dynamical IP address to network.
The modem changes own IP address after 
some time and then tries log on to network 
with the same interface address. In this case 
the Local DNS server thinks that the next 
modem log on to the network with the same 

interface address and decline it. 

GPRS – 
communication 
speed 

--- 

Communication speed between modem CPU 
and GSM/GPRS module information. 

GPRS – registration 
period 

0 up to 999999 s 

Registration period is time how often the 
modem repeats first log in to the local DNS. 

GPRS – Heart Beat 
period 

0 up to 255 min 

Heart beat period is time when the modem 
repeats log in to the local DNS after 
successful log in. By this the modem checks 
active connection with local DNS. 

GPRS – timeout for 
disconnection 

0 up to 255 s 

The modem checks CTS control signal from 
module. If the CTS signal is inactive after this 
timeout the GPRS connection is inactive and 
will be new log in to the GPRS. 

Acknowledge time 
out 

100 up to 25500 

msec 

After this timeout the modem wait to sent 
message acknowledge. 

Transmit attempts 

1 up to 5 

Parameter sets the maximal number of data 
transmission repetition. 

Packet maximum 
length 

128 up to 1000 

Parameter set maximal possible length
of sending data message, the 

maximal 

adjustable message length is 1000 bytes. 

Attempts for PPP init 
connection 

1 up to 16 

Parameter set attempts number of
the transmitted control LCP/IPCP frames 
behind PPP connection establishment. 

Firmware version 

--- 

Parameter shows modem firmware number, 
only for information. 

Automatic reset 
interval 

0 up to 999999 min

Parameter set period after which the modem 
will be reset. 

Transferred data limit 

0 up to 65535 kB 

If this data limit is proceed it will send size 

data information to the global DNS. The data 
communication is next allowed and possible. 

GPRS – firmware 
version 

--- 

IGSM/GPRS module firmware version 
information. 

Содержание CGU 04i

Страница 1: ...GPRS modem CGU 04i USER S GUIDE Declared system ISO 9001 2009...

Страница 2: ...2 Connector PORT2 CNT 20 2 7 5 CIO connector 21 2 7 6 PWR supply connector 23 2 8 Antenna connection 25 2 9 Technical specifications of port 2 25 2 10 CGU 04i settings 28 2 11 Service cable 28 2 12 S...

Страница 3: ...g CIO signals to user device 49 6 REFERENCES 51 7 LINKS TO RELATED PRODUCTS OF THE MANUFACTURER 51 7 1 Systems 51 7 2 Protocols 51 7 3 Software 51 7 4 Products 51 8 PRODUCT DISPOSAL INFORMATION 52 9 C...

Страница 4: ...Caution The SIM card could be swallowed by small children Voltage at the feed connector of the communication module must not be exceeded Do not expose the communication module to extreme conditions P...

Страница 5: ...ransfer on serial user interfaces and a number of diagnostic and service features CGU 04i module in the basic version has one serial user interface communication port RS232 one interface for direct co...

Страница 6: ...ocesses simultaneous tasks Thus parallel operation of all external interfaces of the communication module is maintained The microprocessor is connected through serial interface to MC39i OEM module and...

Страница 7: ...mA Reading and control of I O signals is possible from the remote CGU 04i module or any serial user interface Simple technological interface can be created by configuration of two CGU 04i modules wher...

Страница 8: ...protocol directly by the customer In case of M BUS expansion board installed and when chosen protocol is not M BUS or M BUS TCP then sent data will be returned back to the device If e g LINE protocol...

Страница 9: ...ception 2 x Time slot max 42 8 kb s 4 x Time slot max 85 6 kb s Temperature range Function Storage 20 o C to 55 o C 40 o C to 85 o C Supply voltage 10 to 30 V DC Consumption GPRS TX GPRS on line GSM s...

Страница 10: ...ther with PWR station activation failed Inverse flashing to PWR no DNS connection Off GSM GPRS communication established Flashes dimly GPRS transmission or reception z Serial connection Establishment...

Страница 11: ...panel The two PORT1 and PORT2 optional connectors are for user interfaces The fourth PWR connector is for supply adapter connection Antenna is connected to the last ANT connector There is RJ45 CIO con...

Страница 12: ...Input 2 CTS Clear To Send Output 3 DTR Data Terminal Ready Input 4 DSR Data Set Ready connected to 4 V through 330 Ohm Output 5 GND GROUND signal ground 6 RXD Receive Data Output 7 CD Carrier Detect...

Страница 13: ...ion to the CGU 04i z Cable KD2 is connected to serial port PC example COM1 Example of the RS232 equipment connection to the CGU 04i possibility to use all RS232 ports Cable KD 2 Modem CGU 04i PORT1 PO...

Страница 14: ...l not active 2 7 3 Connector PORT2 RS485 Panel socket RJ45 Pin number Signal mark Description Direction 1 GND Signal and supply ground 2 GND Signal and supply ground 3 TxRx RS485 B Input Output 4 TxRx...

Страница 15: ...an 10m it is need to use overvoltage protection on the modem side Pin 1 SGDN Pin 2 SGND Pin 3 RS485 Pin 4 RS485 Pin 5 RS485 Pin 6 RS485 Pin 7 12V EXT Pin 8 12V EXT Modem CGU 4i SGND RS485 RS485 Meter...

Страница 16: ...Transmit Data Input Output 7 12V EXT External supply 8 12V EXT External supply ATTENTION Power supply is selected on the expansion port RS422 by help of a jumper ref 2 9 If galvanic separation is req...

Страница 17: ...ength more than 10 m At RS422 data cable more than 10m it is need to use overvoltage protection on the modem side 1Y 2Y DC Meter SGND TxD TxD RxD RxD Modem CGU 04i Pin 1 SGND Pin 2 SGND Pin 3 RxD Pin...

Страница 18: ...nput Output 6 TxRx MBUS A Input Output 7 12V EXT External supply 8 12V EXT External supply BEWARE External supply is for converter MBUSD If galvanic separation is required the converter must have exte...

Страница 19: ...more than 10 m If an M BUS data cable more than 10m it is need to use overvoltage protection on the router side DC Meter SGND MBUS MBUS Meter SGND MBUS MBUS Modem CGU 04i Pin 1 SGND Pin 2 SGND Pin 3...

Страница 20: ...n Direction 1 BIN0 CNT0 Binary input counter input Input 2 BIN1 CNT1 Binary input counter input Input 3 BIN2 Binary input Input 4 BIN3 Binary input Input 5 GND Signal ground 6 OUT0 Binary output Outpu...

Страница 21: ...n collector Input Output 3 I O 3 Input Output analogue or binary input or binary output open collector Input Output 4 12V Output 12V supply of other circuits connected directly to modem supply Output...

Страница 22: ...addresses are automatically assigned In the direction from modem the addresses raises uplink 1 2 3 4 and 5 Maximal module number in series is five See reference 4 CIO 2 OpI binary input CIO 2 AnI anal...

Страница 23: ...V 5 GND Negative pole of DC supply voltage 6 GND Negative pole of DC supply voltage Note Clamps 1 4 UN and 5 6 GND are in the modem connect for bigger current overload On the power supply connector it...

Страница 24: ...ery with present supply monitoring DC supply with backup battery without present supply monitoring DC Modem CGU 04i Pin 1 UN Pin 2 NC Pin 3 INAC Pin 4 UN Pin 5 GND Pin 6 GND DC Modem CGU 04i Pin 1 UN...

Страница 25: ...Emission EN 55022 B Immunity ETS 300 342 Safety EN 60950 M BUS specifications SN EN 1434 Max devices each 1 5 mA 30 Max operating bus current 60 mA Overload protection 100 mA Short circuit strength p...

Страница 26: ...s required jumpers J2 and J3 must be connected to pins 2 3 Internal power supply is made by connecting pins 1 2 with jumpers J2 and J3 Interface behavior of module Expansion port RS485 RS422 can be ma...

Страница 27: ...x bit rate 230400 bps Max overvoltage 30 V Max total cable length 300Bd 200nF km 20 m for product Expansion port CNT Expansion port CNT Power supply Internal Sleep 100 A counter is functional Operatio...

Страница 28: ...ngs but service interventions in the data network as well The basic setting of the radio modem is in 5 Data cable KD 2 CGU 04i module settings can be done remotely via GPRS Remote configuration access...

Страница 29: ...RJ45 connectors for data cables and CIO connection 3 Compliance certificate 4 Complaint procedure 5 Warranty 6 User manual 2 13 Additional accessories 1 Supply adapter 2 AO AGSM FME V antenna 3 Modul...

Страница 30: ...CGU 04i DESCRIPTION 30 2 14 Assembly procedure CGU 04i module is designed as a standard for 1 Assembly to a panel using the through holes Through hole for assembly...

Страница 31: ...CGU 04i DESCRIPTION 31 2 DIN 35 mm rail assembly using plastic grips 3 To be put on a worktop...

Страница 32: ...s to switch board the following it is not need have no examination immunity or issues in connection with EMC according to EN 60439 1 A1 For compliance of EN 60439 1 A1 specification it is necessary ob...

Страница 33: ...es can be maximum 1 5 m if length of data cables exceeds 1 5 m or in the event of the cable leads towards the switch board we recommend to use fit over voltage protectors surge suppressors with data c...

Страница 34: ...r correct function of the modem we recommend to use in switch board earth bonding distribution frame for grounding of power supply of modem data cables and antenna z the circuit diagram of the modem i...

Страница 35: ...g Trade name Type name Supply Other Expansion port RS232 XC 232 Internal from module CGU 04i Expansion port RS485 RS422 XC 485 422 External or internal Round variation RS 485 422 it is possible choose...

Страница 36: ...CGU 04i DESCRIPTION 36 2 19 Expansion ports labels...

Страница 37: ...et own IP address of the SIM card By this is faster registration to the network some operators not support this function Direct IP address x x x x Parameter sets direct IP address on which will be sen...

Страница 38: ...with Global DNS server Modem which isn t right activated isn t accessible from any other modem in network and isn t able send any data to other modem itself In this case the modem isn t able communica...

Страница 39: ...r disconnection 0 up to 255 s The modem checks CTS control signal from module If the CTS signal is inactive after this timeout the GPRS connection is inactive and will be new log in to the GPRS Acknow...

Страница 40: ...n the GSM registration drop is longer than set this parameter the modem try establish new connection Minimal successful GPRS connect time 0 up to 65535 s When three successful GPRS connect time are sm...

Страница 41: ...tored to the journal Log COM ports YES NO When this parameter is set to YES than COM information are stored to the journal Log PPP protocol YES NO When this parameter is set to YES than PPP informatio...

Страница 42: ...transfer statistic If number of lost packet is low signal quality is good 3 2 Good quality GPRS requirements z serving cell signal better than 90dBm z adjacent cell signal below 12dB to serving cell...

Страница 43: ...BCCH carrier in dBm PLMN PLMN ID code LAC location area code cell cell ID NCC PLMN colour code BCC base station colour code PWR maximal power level used on RACH channel in dBm RXLev minimal receiving...

Страница 44: ...CN Absolute Frequency Channel Number of the BCCH carrier rs RSSI value 0 63 RSSI Received signal strength indication dBm Receiving level in dBm PLMN PLMN ID code BCC Base Station colour code C1 coeffi...

Страница 45: ...bottom part position 3 and carried out box top part position 2 the expansion port PORT2 position 6 connect to connector J3 see below of the router B CGU 04i motherboard position 1 from TOP side Expan...

Страница 46: ...scription Number 1 Modem CGU 04i motherboard 1 2 CGU 04i box top part 1 3 CGU 04i box bottom part 1 4 CGU 04i rear head 1 5 CGU 04i front head 1 6 Expansion port 1 7 Distant columns for expansion port...

Страница 47: ...checked every 100 ms from the analogue input transferred to digital ten bit value and adjusted by calibration constant The value is further average computed according to user interface and saved in th...

Страница 48: ...30 V The signal is protected against overvoltage by a protection element that blocks voltage in excess of 16 V INAC is designed for measuring of network supply voltage presence The change of the valu...

Страница 49: ...ly connector see the supply connector description It is connected as universal I O signal outputs This is an open collector that switches PWRSV signal to the ground GND The output is controlled by a r...

Страница 50: ...Binary input One galvanically separated digital input for AC DC signals up to 30 V on high voltage brackets up to 350 V It includes bipolar optoelement that enables processing both input signal polar...

Страница 51: ...e are another links on Cinterion company website www cinterion com 7 1 Systems AGNES Advanced GPRS Network System represents a solution for private data network structures for industrial applications...

Страница 52: ...ctronic products are recycled using the best available recovery techniques to minimise the impact on the environment This product contains high quality materials and components which can be recycled A...

Страница 53: ...the moment of purchase Caution The vendor is not responsible for keeping default settings or data saved in the subject of the complaint The customer is obliged to clarify the defect or how it is disp...

Страница 54: ...quire remedy through an extra warranty repair under the conditions the device shall be returned to him her after he she pays the demonstrable cost of expert assessment The guarantee does not cover def...

Страница 55: ...WARRANTY 55 10 Warranty Device type Serial number Guarantee period months Vendor Date of purchase Seal of the vendor...

Страница 56: ...tration Complaint protocol number Date of reception of the device in repair shop Date of finished repair Number of repair sheet Warranty repair YES NO YES NO YES NO YES NO YES NO New serial number of...

Отзывы: