- 17 -
08785150
Maintenance
Compressor Oil Fill, Level, and
Drain
Before adding or changing compressor oil, make sure
that the compressor is completely relieved of pressure.
The drain is located inside the service door on the
bottom of the sump tank. To drain the oil, remove the
drain plug in the bottom of the tank.
Oil is added at the fill cap on the side of the machine.
The proper oil level is in the middle of the oil
sightglass when the unit is shut down and has had
time to settle. The machine must be level when
checking the oil. The fill neck is designed to prevent
overfilling; however, care must still be taken to ensure
the proper oil level. DO NOT OVERFILL. The oil
capacity is given in “Compressor Specifications”.
Belt Tensioning Procedure
First, be sure the unit is off and the key is removed.
Then use a 3/4” socket to turn the compressor slide
plate adjustment bolt clockwise to tighten the
compressor belts. Proper belt tensioning is 1/4”
deflection @ 3.3 to 5 lbs of force per belt.
Changing the Air Intake Filter
The air intake filter is a heavy-duty dry type high
efficiency filter designed to protect the compressor
from dust and foreign objects.
Frequency of maintenance of the filter depends on
dust conditions at the operating site. The filter
element must be serviced when clogged. A clogged
air filter element will reduce compressor performance
and cause premature wear of components.
Belt Replacement Procedure
First be sure that the unit is off and they key is
removed. Then use a 3/4” socket to turn the
compressor slide plate adjustment bolt counter
clockwise to loosen the compressor belts. Only loosen
enough to remove belts. Next, remove the old belts
and install the new ones. Use a 3/4” socket to turn the
compressor slide plate adjustment bolt clockwise to
tighten the compressor belts. Proper belt tensioning
is 1/4” deflection @ 3.3 to 5 lbs of force per belt. Use
a belt tensiometer to properly tension the belts.
Do not substitute element. Use only a Condux
International, Inc. approved replacement element.
This element is rated at 350 PSI working pressure.
Use of any non-approved element may be hazardous
and could impair the performance and reliability of
the compressor, possibly voiding the warranty and/or
resulting in damage to property and serious bodily
harm.