Conductix-Wampfler Festoon Heavy Duty C-Track Скачать руководство пользователя страница 14

Contact USA for our Global Sales Offices

www.conductix.us

© Conductix-W

ampfler | 2017 | Subject to 

Technical Modifica

tions 

Without Prior Notice

USA / LATIN AMERICA

10102 F Street
Omaha, NE 68127

Customer Support
Phone +1-800-521-4888

Phone +1-402-339-9300
Fax +1-402-339-9627

[email protected]
[email protected]

CANADA

18450 J.A. Bombardier 
Mirabel, QC J7J 0H5

Customer Support
Phone +1-800-667-2487

Phone +1-450-565-9900
Fax +1-450-851-8591

[email protected]

MÉXICO 

Calle Treviño 983-C
Zona Centro
Apodaca, NL México 66600

Customer Support
Phone  (+52 81) 1090 9519
 

(+52 81) 1090 9025

 

(+52 81) 1090 9013

Fax 

(+52 81) 1090 9014

[email protected]

BRAZIL

Rua Luiz Pionti, 110
Vila Progresso
Itu, São Paulo, Brasil
CEP: 13313-534
Customer Support
Phone  (+55 11) 4813 7330 

Fax    (+55 11) 4813 7357 
 
[email protected]

Heavy Duty C-Track Manual

XA-966300.3

Содержание Festoon Heavy Duty C-Track

Страница 1: ...Festoon Manual Heavy Duty C Track Heavy Duty C Track Manual XA 966300 3...

Страница 2: ...ing goods shall arise once Buyer returns such goods FOB point of original shipment by Seller at the risk and cost of Buyer Goods replaced by Seller shall become the property of Seller There is no guar...

Страница 3: ...ger Installation 7 Track Joint Assemblies Installation 7 Anchor Clamp Installation 8 Girder Clamp Installation 8 End Clamp Installation 8 Cable Trolley Installation 9 Tow Trolley Control Box Trolley I...

Страница 4: ...FETY Safety Information Responsibility All owner operator and maintenance personnel must read and understand all manuals associated with this product before installation operation or maintenance The m...

Страница 5: ...rack Hanger Installation See Section 3 Cable Trolley Installation See Section 3 Cable Installation See Section 3 End Clamp See Section 3 End Stop Installation See Section 3 2 Endstops Needed per Contr...

Страница 6: ...ed The loop depth is the distance from the top of the track to bottom of the cable loop Maximum cable stack height is 1 5 Maximum recommended cable height is 65 For round cable the maximum recommended...

Страница 7: ...ired in storage area 1 Slip the appropriate number of hangers on each section of C Track 2 Bolt the section loosely in place joining the ends of the channels with splice joints as you progress See Fig...

Страница 8: ...s are designed to hold the crossarm supports to the I beam Two girder clamps required per crossarm support 1 Orient square nut flush against inside bottom surface of C Track crossarm support See Figur...

Страница 9: ...ontrol festoon system The Control Box Trolley consists of a mobile junction box or a quick disconnect connector to which a push button pendant may be wired 1 Place the Tow Trolley Control Box Trolley...

Страница 10: ...better suited to handle this force Note the specified cable loop depth and allowance for hookup 4 Arrange the cable package with a width to height ratio of 3 or 4 to 1 Tall narrow cable stacks can be...

Страница 11: ...align tow bar with the Tow Trolley See Figure 11 2 Pre Assembled Festoon System Installation Pre assembled festoon systems are typically built and shipped installed on a C Track Channel by Conductix W...

Страница 12: ...the voltage or amperage rating of the cable Overheating fire damages to equipment or personal injury could result Operate the festoon system within the electrical and mechanical limits it was intende...

Страница 13: ...Heavy Duty C Track Manual 13...

Страница 14: ...ADA 18450 J A Bombardier Mirabel QC J7J 0H5 Customer Support Phone 1 800 667 2487 Phone 1 450 565 9900 Fax 1 450 851 8591 info ca conductix com M XICO Calle Trevi o 983 C Zona Centro Apodaca NL M xico...

Отзывы: