Conductix-Wampfler Festoon Heavy Duty C-Track Скачать руководство пользователя страница 11

Heavy Duty C-Track Manual

         

11 

Tow Webbing Installation

Tow webbing is used in both High Speed and Outdoor applications 
to reduce the shock and pulling tension on the electrical cable.

The tow webbing is installed on top of the electrical cable and held 
in place by the saddle on the cable trolley. See 

Figure 11-1.

The webbing length is generally 3 inches less than cable per loop 
of the length of the cable between cable trolleys. Contact factory 
for high speed applications to determine webbing length. See 

Figure 11-1.

Tow Bar

The tow bar is fixed to the crane and is designed to engage tow 
box to move festoon system.

1.  Install the tow bar on the crane or system that is to be 

electrified. Center and align tow bar with the Tow Trolley. See 

Figure 11-2.

Pre-Assembled Festoon System Installation

Pre-assembled festoon systems are typically built and shipped 
installed on a C-Track Channel by Conductix Wampfler. 

Upon arrival at the job-site, inspect the festoon system to insure 
electrical cables and festoon components have not been damaged 
during transit.

1.  Attach hoisting cables at each end of the pre-assembled 

festoon C-Track and lift into position. The shipping C-Track 
mobile end must align with the permanent festoon C-Track.

2.  Remove the end stop from the mobile end of temporary 

C-Track and roll the Tow / Control Box trolley and succeeding 
cable trolleys into the permanent C-Track.

3.  Make mechanical connections of towing arm and insure all 

end stops are applied and tightened.

4.  Make electrical connections as required.

SECTION 3 - INSTALLATION

Figure 11-1

1.  Trolley
2.  Tow Webbing

Figure 11-2

1

2

Содержание Festoon Heavy Duty C-Track

Страница 1: ...Festoon Manual Heavy Duty C Track Heavy Duty C Track Manual XA 966300 3...

Страница 2: ...ing goods shall arise once Buyer returns such goods FOB point of original shipment by Seller at the risk and cost of Buyer Goods replaced by Seller shall become the property of Seller There is no guar...

Страница 3: ...ger Installation 7 Track Joint Assemblies Installation 7 Anchor Clamp Installation 8 Girder Clamp Installation 8 End Clamp Installation 8 Cable Trolley Installation 9 Tow Trolley Control Box Trolley I...

Страница 4: ...FETY Safety Information Responsibility All owner operator and maintenance personnel must read and understand all manuals associated with this product before installation operation or maintenance The m...

Страница 5: ...rack Hanger Installation See Section 3 Cable Trolley Installation See Section 3 Cable Installation See Section 3 End Clamp See Section 3 End Stop Installation See Section 3 2 Endstops Needed per Contr...

Страница 6: ...ed The loop depth is the distance from the top of the track to bottom of the cable loop Maximum cable stack height is 1 5 Maximum recommended cable height is 65 For round cable the maximum recommended...

Страница 7: ...ired in storage area 1 Slip the appropriate number of hangers on each section of C Track 2 Bolt the section loosely in place joining the ends of the channels with splice joints as you progress See Fig...

Страница 8: ...s are designed to hold the crossarm supports to the I beam Two girder clamps required per crossarm support 1 Orient square nut flush against inside bottom surface of C Track crossarm support See Figur...

Страница 9: ...ontrol festoon system The Control Box Trolley consists of a mobile junction box or a quick disconnect connector to which a push button pendant may be wired 1 Place the Tow Trolley Control Box Trolley...

Страница 10: ...better suited to handle this force Note the specified cable loop depth and allowance for hookup 4 Arrange the cable package with a width to height ratio of 3 or 4 to 1 Tall narrow cable stacks can be...

Страница 11: ...align tow bar with the Tow Trolley See Figure 11 2 Pre Assembled Festoon System Installation Pre assembled festoon systems are typically built and shipped installed on a C Track Channel by Conductix W...

Страница 12: ...the voltage or amperage rating of the cable Overheating fire damages to equipment or personal injury could result Operate the festoon system within the electrical and mechanical limits it was intende...

Страница 13: ...Heavy Duty C Track Manual 13...

Страница 14: ...ADA 18450 J A Bombardier Mirabel QC J7J 0H5 Customer Support Phone 1 800 667 2487 Phone 1 450 565 9900 Fax 1 450 851 8591 info ca conductix com M XICO Calle Trevi o 983 C Zona Centro Apodaca NL M xico...

Отзывы: