Zero calibration
Press
Activate zero calibration
It is necessary to take the sensor away from
foreign objects by 20cm.
Zero calibration is valid for the selected sensor
only.
To calibrate other sensors, one should be selected
by short press button
Press
Zero calibration
Zero calibration allows setting the initial humidity
sensor readings to zero. Zero calibration should
be carried out at 10-15 minute intervals in order to
compensate the errors
MEASUREMENTS
Single measurement
Press
Switch on the device.
Press
Perform zero calibration (check paragraph «Zero
calibration»)
Press
Select the material (wood; concrete)
Press and
Select the group of measured material
Press
Select the sensor (front; bottom 15 mm; bottom
30mm)
To obtain reliable measurement results, it is
necessary to ensure proper contact of the
sensor with the surface (there should be no
gaps between the sensor and the surface) and
check the measurement result on the display.
Tested surface should be smooth and clean, as
homogeneous as possible, without deep dents
and protrusions. The sensor should be pressed
with a force of about 1kg.
The result of humidity measurement of the site
(sample) is:
* for wood - the average value of at least three
measurements
* for concrete - average value of no less than five
measurements
Содержание HYDRO PRO
Страница 1: ......
Страница 20: ...38 RU 39 RU HYDRO PRO CONDTROL HYDRO PRO CONDTROL 3 5 10 15 5 10 15 5 0 5 4 1...
Страница 21: ...40 RU 41 RU HYDRO PRO CONDTROL HYDRO PRO CONDTROL 15 30 1 20 10 15...
Страница 22: ...42 RU 43 RU HYDRO PRO CONDTROL HYDRO PRO CONDTROL 0 0 5 EMC Tp...
Страница 23: ...44 RU 45 RU HYDRO PRO CONDTROL HYDRO PRO CONDTROL 2006 66 24 www condtrol ru 10 2002 96...
Страница 33: ......