background image

Quick Start Guide

Condair HumiLife

– The economic solution for forced air heating

Condair RE

READ AND SAVE THESE INSTRUCTIONS

2

5

9

8

3

8

0

_

B

_

E

N

_

2

0

0

5

_

C

o

n

d

a

ir

-R

E

_

S

IO

M

Humidification and Evaporative Cooling

Содержание HumiLife RE Series

Страница 1: ...Quick Start Guide Condair HumiLife The economic solution for forced air heating Condair RE READ AND SAVE THESE INSTRUCTIONS 2598380_B_EN_2005_Condair RE_SIOM Humidification and Evaporative Cooling...

Страница 2: ...r choosing Condair What s in the box l Condair HumiLife RE Humidifier l 24 VDC power supply l Mounting template l Saddle valve l Inlet hose l Drain hose l Clip for drain hose l Quick connector l Self...

Страница 3: ...2598380_B_EN_2005_Condair RE_SIOM 3 Product Overview Hose Ceramic media LEDs Control board Top cover Damper Damper switch Bottom cover Solenoid valve Water supply Drain...

Страница 4: ...4 2598380_B_EN_2005_Condair RE_SIOM Installation Overview 24 VDC 120 VAC Air duct Condair HumiLife RE Bypass duct Water supply Power supply 24 VDC Furnace Humidity sensor Drain...

Страница 5: ...ON ON DUCT CUT METAL DUCT ALONG OUTLINE ADHERE TEMPLATE TO DESIRED POSITION ON DUCT CUT METAL DUCT ALONG OUTLINE ENSURE ARROW UP 12 in 305 mm 9 45 in 240 mm 6 in 150 mm 6 in 150 mm 6 in 150 mm 6 in 15...

Страница 6: ...ired Change the orientation of the bypass opening a Remove the top cover then the bottom cover of the humidifier b Push in the tabs and push out the end cap and bypass opening Switch their positions c...

Страница 7: ...installed l For the plastic water line supplied from the saddle valve to the humidifier a Place the brass compression nut over one end of the plastic water line Ensure the wider opening of the nut fa...

Страница 8: ...addle valve to allow water to enter the new line Connecting the Drain Line 1 Connect the drain line to the spout on the humidifier and secure the hose with hose clamps 2 Route the drain hose to a suit...

Страница 9: ...5V GND Signal 1AT PB1 Sig 0 10 V 0 20 mA Power 24VDC Inlet Valve Controls Safety Chain Sensors 1 and 2 IMPORTANT Unit accepts 24 VDC only Adhere to all local and regional electrical codes 1 Ensure ext...

Страница 10: ...ress Add Device Follow on screen instructions Press and hold the power button on the humidifier for 5 seconds the WiFi LED will start flashing Once the connection is established follow the on screen i...

Страница 11: ...lled in accordance with local plumbing codes by a licensed plumber Condair does not accept any liability for installations of humidity equipment installed by unqualified personnel or the use of parts...

Страница 12: ...in writing signed by an officer of THE COMPANY THE COMPANY s parts or materials that are considered consumables including but not limited to cylinders filters nozzles membranes media gaskets O rings...

Отзывы: