background image

HAVELLS SYLVANIA EUROPE LTD

Avis Way Newhaven East Sussex

BN9 0ED

www.havells-sylvania.com

30 cm 

÷

3  cm 

installation and maintenance sheet

Pathè G/D

frame

upper casing  

level flushing  

to roadside

BEAM ADJUSTMENT 

The 4 beam model can reduce the number of beams and rotate them on the vertical axis.

• Cut off power from mains before carrying out any type of maintenance.

•  Remove the fixture from the outer casing and take it to the edge of ground (pict.4).

• Carefully clean the fixture before opening it by the help of a big brush and a humid cloth.

• Unscrew the frame (pict.5)

•  The  LED  support  can  be  turned  in  clockwise  and  anti-clockwise  direction  up  to  90° 

 

   so to direct the light beam (pay attention to the cables underneath) (pict. 6)

• To reduce the number of beams from 4 to 3 or 2 add respectively 1 or 2 stoppers      

 

   (supplied with the fixture) in the screen (pict. 6)

•  Great  care  must  be  taken  avoiding  dirtying  the  gaskets  and  relative  support  ledge. 

Check the gasket and replace it if deformed. Make sure that the gasket is dead-centred 

in its housing. For a correct operation it is necessary to arrange the unit so that its 

mouth is horizontal.

•  it is essential a frequent cleaning of the glass and of the outer surface of the fixture to 

avoid build up of mud and dirtiness resulting in dangerous overheating due to uncorrect 

light and heath dissipation.

•  important:  in  the  event  of  damage  to  the  H07RN-F  cable,  breakage  of  the  screen, 

infiltration of water, the appliance cannot be used. Disconnect it from the mains supply 

and contact our company or our sales organization for replacement/repair.

well tamped sand and 

gravel backfill

fixture outer 

casing

sand and gravel 

draining foundation, 

hosed until refusal, 

well set and tamped

concrete block

lean concrete

pict. 2

pict. 3

draining layer

support bricks 

fixed with a trowel 

of mortar

connection  

accessory 4068964

prefabricated pit

30x30x30cm 

approx.

electric cables

pict. 1

YES

NO

external housing 

unit

connection  

accessory 4068964

pict. 4

pict. 5

pict. 6

electric cables

Version in Class I 

: earth required

Version in Class II 

: earth not required 

 

 

 

 

 

IP66 - IP67   totally  dust-proof  and  watertight  against  powerful  water  jets

 

will operate if occasionally submerged

  

   heavy duty:    

 

 

 

 

can withstand impacts up to 6.5 Nm

  

    mounting on normally     

 

 

inflammable surfaces allowed

 

  

replace the protection screen if damaged 

 

  with  a  plane  float  tempered  glass  –  thickness  10  mm, 

 

 

  shock resistant 6.5Nm according to EN60598-1

  

    getting rid of as urban waste forbidden  

 

 

separate collection is mandatory when the  

 

 

product is at the end of its life

EMBEDDED INSTALLATION WITHOUT PASSAGE OF VEHICLES

for correct assembly, proceed as follows:

1)         avoid positioning the fixture in areas of subsidence (pict.1) where dirt and stagnant 

water can accumulate. 

    Picture 2

2)          make a hole (boring) in the ground with a diameter of approximately 40 cm and approximately 

 

50 cm deep.

3)       square  the  upper  part  of  the  hole  by  inserting  a  prefabricated  pit  of  approximately 

30x30x30  cm.  The  upper  edge  of  the  pit  must  be  about  2/3  cm  higher  than  the 

surrounding ground to which it must be connected with an outer slope for the run-off 

of water and to avoid the accumulation of dirt.

4)       backfill the hole with a mixture of sand and gravel up to a distance of about 25 cm from 

the upper edge of the pit. Hose with plenty of water until refusal and tamp the mixture 

in such a way as to form a compact and homogenous draining layer.

5)       place four bricks with a trowel of mortar on the bottom of the pit in order to form a solid 

support base for the outer casing of the fixture which must protrude about 2/3 cm with 

respect to the edge of the prefabricated pit.

6)                backfill  the  pit  around  the  casing  with  a  mixture  of  well  tamped  and  set  sand 

and  gravel,  arranging  the  cables  for  the  electrical  connection  of  the  fixture.

 

EMBEDDED INSTALLATION WITH PASSAGE OF VEHICLES

proceed as in the above points 1-2-3-4.

5)  refer to pict.3, prepare lean concrete cement on which to place the block of concrete, 

taking care to leave a hole with a diameter of at least 12 cm for drainage. Provide for 

the passage of electrical wires. 

6)   insert the outer casing of the fixture into a concrete foundation block, batched at 200 

kg of 325 type cement per cubic metre of mixture. The block must have a diameter (or 

side) of not less than 30 cm. Line up carefully the upper edge of the outer casing with 

the trampling level as per pict. 3.

ELECTRICAL CONNECTION

Important: the electrical connection must be carried out by a skilled 

electrician

. Important: 

in  the  case  of  damage  of  the  appliance,  there  may  be  a  reduction  in  the  degree  of 

protection  with  consequent  infiltration  of  water  and  loss  of  insulation.  Therefore, 

additional protection should be inserted into the electrical plant against direct contacts 

(for example a high sensitivity differential switch). During installation, fully respect the 

current rules on electrical systems.

• For the electrical connection use a flexible <HAR> rubber cable cross-section 1x1.5mm 

2

.  

The fixtures are complete with a piece of H07RN-F cable which is pre-connected and sealed. 

 

For a rapid and safe connection with the electric line use the connector 4068964 or an 

equivalent system that guarantees at least the IP67 degree.

LED VERSION - RISK GROUP 2: 

CAUTION: Possibly hazardous optical radiation emitted from this product. Do not stare 

at operating lamp. May be harmful to the eye. The electrical circuit complete with leds 

has to be required to our company or its distributors. The replacement must be done by 

a qualified electrician.

Features and meaning of the symbols shown on the label:

•  lighting  appliance  for  indoor  and  outdoor  ground-recessed  installation.

  

Capable of withstanding the load of motor vehicles with inflatable tyres pumped with 

air, maximum weight static or dynamic: 2000Kg.

Quality control: Should you have any complaint please get in touch with our company or its sales organization. Please give the number of your order as well as the serial number 

that recognizes the fixture.

version Class I

Pathè G/D

max. glas Temp. ta 25°C

40° C

  Fixtures  that  can  be  utilized  in  all  accessible  areas,  according  to  EN60598-2-13 

 

Pedestrian over, with max. glass temp. of 75°C  

 

 

 

20kN static load resistance.

•  Do not install in areas where snowplows are used.

NB: These assembly instructions must be given to end users for correct maintenance and so that they know how to change the bulb. The appliance must not be tampered with or transformed and it must 

be installed  and used as supplied and in compliance with the National Rules on Installations. Any non-compliant installations will invalidate all forms of guarantee. The company cannot be held responsible 

for damage caused by incorrect assembly. PRECAUTIONS FOR ASSEMBLY - IMPORTANT! As it is a drive-over ground-recessed appliance, great care must be taken in installation, scrupulously following 

the assembly instructions specified here. • The appliance is tested for the penetration of water. • The appliance should be positioned and installed when closed, with the bulb already mounted and correctly 

adjusted in order to avoid dirt entering and compromising  its watertightness.

  product in compliance with the requirements

  of the European Community Directories

93 

118 

25 

Ø170 

Ø148 

7 mm 

MI/1753-C - 3

a

 edition - 05/2012

 IS13163

Отзывы: