installation and maintenance sheet
Pathè G/D
frame
upper casing
level flushing
to roadside
BEAM ADJUSTMENT
The 4 beam model can reduce the number of beams and rotate them on the vertical axis.
• Cut off power from mains before carrying out any type of maintenance.
• Remove the fixture from the outer casing and take it to the edge of ground (pict.4).
• Carefully clean the fixture before opening it by the help of a big brush and a humid cloth.
• Unscrew the frame (pict.5)
• The LED support can be turned in clockwise and anti-clockwise direction up to 90°
so to direct the light beam (pay attention to the cables underneath) (pict. 6)
• To reduce the number of beams from 4 to 3 or 2 add respectively 1 or 2 stoppers
(supplied with the fixture) in the screen (pict. 6)
• Great care must be taken avoiding dirtying the gaskets and relative support ledge.
Check the gasket and replace it if deformed. Make sure that the gasket is dead-centred
in its housing. For a correct operation it is necessary to arrange the unit so that its
mouth is horizontal.
• it is essential a frequent cleaning of the glass and of the outer surface of the fixture to
avoid build up of mud and dirtiness resulting in dangerous overheating due to uncorrect
light and heath dissipation.
• important: in the event of damage to the H07RN-F cable, breakage of the screen,
infiltration of water, the appliance cannot be used. Disconnect it from the mains supply
and contact our company or our sales organization for replacement/repair.
well tamped sand and
gravel backfill
fixture outer
casing
sand and gravel
draining foundation,
hosed until refusal,
well set and tamped
concrete block
lean concrete
pict. 2
pict. 3
draining layer
support bricks
fixed with a trowel
of mortar
connection
accessory 4068964
prefabricated pit
30x30x30cm
approx.
electric cables
pict. 1
YES
NO
external housing
unit
connection
accessory 4068964
pict. 4
pict. 5
pict. 6
electric cables
Version in Class I
: earth required
Version in Class II
: earth not required
IP66 - IP67 totally dust-proof and watertight against powerful water jets
will operate if occasionally submerged
heavy duty:
can withstand impacts up to 6.5 Nm
mounting on normally
inflammable surfaces allowed
replace the protection screen if damaged
with a plane float tempered glass – thickness 10 mm,
shock resistant 6.5Nm according to EN60598-1
getting rid of as urban waste forbidden
separate collection is mandatory when the
product is at the end of its life
EMBEDDED INSTALLATION WITHOUT PASSAGE OF VEHICLES
for correct assembly, proceed as follows:
1) avoid positioning the fixture in areas of subsidence (pict.1) where dirt and stagnant
water can accumulate.
Picture 2
2) make a hole (boring) in the ground with a diameter of approximately 40 cm and approximately
50 cm deep.
3) square the upper part of the hole by inserting a prefabricated pit of approximately
30x30x30 cm. The upper edge of the pit must be about 2/3 cm higher than the
surrounding ground to which it must be connected with an outer slope for the run-off
of water and to avoid the accumulation of dirt.
4) backfill the hole with a mixture of sand and gravel up to a distance of about 25 cm from
the upper edge of the pit. Hose with plenty of water until refusal and tamp the mixture
in such a way as to form a compact and homogenous draining layer.
5) place four bricks with a trowel of mortar on the bottom of the pit in order to form a solid
support base for the outer casing of the fixture which must protrude about 2/3 cm with
respect to the edge of the prefabricated pit.
6) backfill the pit around the casing with a mixture of well tamped and set sand
and gravel, arranging the cables for the electrical connection of the fixture.
EMBEDDED INSTALLATION WITH PASSAGE OF VEHICLES
proceed as in the above points 1-2-3-4.
5) refer to pict.3, prepare lean concrete cement on which to place the block of concrete,
taking care to leave a hole with a diameter of at least 12 cm for drainage. Provide for
the passage of electrical wires.
6) insert the outer casing of the fixture into a concrete foundation block, batched at 200
kg of 325 type cement per cubic metre of mixture. The block must have a diameter (or
side) of not less than 30 cm. Line up carefully the upper edge of the outer casing with
the trampling level as per pict. 3.
ELECTRICAL CONNECTION
Important: the electrical connection must be carried out by a skilled
electrician
. Important:
in the case of damage of the appliance, there may be a reduction in the degree of
protection with consequent infiltration of water and loss of insulation. Therefore,
additional protection should be inserted into the electrical plant against direct contacts
(for example a high sensitivity differential switch). During installation, fully respect the
current rules on electrical systems.
• For the electrical connection use a flexible <HAR> rubber cable cross-section 1x1.5mm
2
.
The fixtures are complete with a piece of H07RN-F cable which is pre-connected and sealed.
For a rapid and safe connection with the electric line use the connector 4068964 or an
equivalent system that guarantees at least the IP67 degree.
LED VERSION - RISK GROUP 2:
CAUTION: Possibly hazardous optical radiation emitted from this product. Do not stare
at operating lamp. May be harmful to the eye. The electrical circuit complete with leds
has to be required to our company or its distributors. The replacement must be done by
a qualified electrician.
Features and meaning of the symbols shown on the label:
• lighting appliance for indoor and outdoor ground-recessed installation.
Capable of withstanding the load of motor vehicles with inflatable tyres pumped with
air, maximum weight static or dynamic: 2000Kg.
Quality control: Should you have any complaint please get in touch with our company or its sales organization. Please give the number of your order as well as the serial number
that recognizes the fixture.
version Class I
Pathè G/D
max. glas Temp. ta 25°C
40° C
Fixtures that can be utilized in all accessible areas, according to EN60598-2-13
Pedestrian over, with max. glass temp. of 75°C
20kN static load resistance.
• Do not install in areas where snowplows are used.
NB: These assembly instructions must be given to end users for correct maintenance and so that they know how to change the bulb. The appliance must not be tampered with or transformed and it must
be installed and used as supplied and in compliance with the National Rules on Installations. Any non-compliant installations will invalidate all forms of guarantee. The company cannot be held responsible
for damage caused by incorrect assembly. PRECAUTIONS FOR ASSEMBLY - IMPORTANT! As it is a drive-over ground-recessed appliance, great care must be taken in installation, scrupulously following
the assembly instructions specified here. • The appliance is tested for the penetration of water. • The appliance should be positioned and installed when closed, with the bulb already mounted and correctly
adjusted in order to avoid dirt entering and compromising its watertightness.
product in compliance with the requirements
of the European Community Directories
93
118
25
Ø170
Ø148
7 mm
MI/1753-C - 3