6
CONNECTING ALARM TO PROTOCOL STATION
The Advantium 1
Plus
Remote Alarm is designed to interface to CONCOA’s Protocol
Stations. The 6-pin remote alarm interface connector is located at the bottom of the
Advantium 1
Plus
Alarm enclosure (See Figure 1). There are two ways to connect the
product to a protocol station. Ready made cable assemblies for connecting the
Advantium 1
Plus
Alarm to a protocol station are available from the factory. Contact
your local CONCOA Distributor or call 1-800-225-0473 for information. The other
option is to build your own cable assembly to connect the two devices. For convenience,
a mating 6-pin connector is provided to use in building this cable assembly. The protocol
station also comes with a mating connector that is used to attach to the protocol side of
the cable assembly. The recommended cable for this assembly is 22 AWG, 4-conductor
stranded wire (Alpha # 1174C or equivalent). The length of this cable should be limited
to 1500 feet.
Cut the 4-conductor cable to length. Remove the outer jacket of the cable to expose
approximately 3/4 inch of the internal conductors on both sides of the cable. Strip away
1/4-inch of the insulation on each of the conductors.
On the 6-pin connector, slide the protective cover, cable retainer, and locking nut over the
end of the cable as shown in
Figure 4
.
Figure 4
Figure 5