7.3 THERMAL CUT-OUT (TCO) RESET
Be aware of high voltage in the
block area. The electrical supply
should be switched off before
working in the heater block
compartment.
This operation is usually
carried out during
installation. If the Smoke
Screen has been in
service, the nozzles will
be extremely hot and
will cause injury if touched.
Therefore, the Smoke Screen
should be switched off and time
should be allowed for the nozzles
to cool.
In the unlikely event that the temperature in the heater block increases significantly above the set working
temperature the TCO will trip to protect the machine from damage. The TCO can be reset using the following
procedure:
•
Make sure the mains power to the machine is turned off before resetting the TCO.
•
Reset the TCO by pressing on the little button on the top area that is accessed through the hole in
protective cover (see photo below). If the thermal device has tripped it should be possible to hear a
click when it resets.
•
Switch on the mains power after resetting.
•
Check the machine heats up to normal operating temperature and make sure it archives a ready state.
See the operating “LCD, LED and Sound Indications” for further information on fault indications.
NB: A TCO usually only trips if there is a problem. If it trips again the Smoke Screen should be checked for faults before
further use.
Note: The position of the TCO can be different depending on the machine version