Servicing
7
7.1 LCD LIVE STATUS INDICATIONS
The Smoke Screen provides ‘Live Status’ indications on the LCS to give a quick overview of the current condition of
the machine. The indications have the following meanings:
Top Line (Outputs):
Indication
Meaning
Explanation
TS
Temp Status
There is a Heater fault or the Smoke Screen is not
Ready.
V
Verify Smoke
The Smoke Screen is active / pump running.
M
Mains Fault
The Mains Power input has failed.
B
Battery Fault
The batteries are not fitted or are switched off or there
is a charging fault.
E
Empty Fluid
The Swift-Fit is empty (Smoke Screen will not produce
smoke).
L
Low Fluid
The Swift-Fit fluid level is less than 50%.
TI
Tamper Internal
The Tamper Output is giving a tamper alarm.
Bottom Line (Inputs):
Indication
Meaning
Explanation
Set
Set
The Set input is armed.
Trg
Trigger
The Trigger input is in an alarm state.
Ho
Hold-off
The Hold-off input is in an alarm state.
Sm
Service Mode
The Service Mode Dip switch is selected on.
ES
Energy Save Mode
Energy Save Mode is enabled.
24