Setting Fluid Capacity.
In the “Setting Fluid Capacity” display press
Enter/Back
to show the current fluid
capacity set. Use
Up
and
Down
buttons to move up and down to select 500ml, 1,000ml, 5,000ml or “Fluid
Sensor on”. Only “500ml” or “5,000ml” should be used on the S70 and S100; see the “Fluid Management”
section for information on the latter. Press
Enter/Back
to save the new setting and return to the higher level
menu. Press
Function/Escape
to return to the higher level menu without saving changes. The delivery Fluid
Capacity Setting is “Fluid sensor on”.
●
Setting Temperature.
This is preset at manufacture and should only be altered by Concept Smoke Screen.
●
Setting Smoke Mode.
In the “Setting Smoke Mode” display press
Enter/Back
to show the current smoke
mode set. Use the
Up
and
Down
buttons to move up and down to select “Turbo Mode” or “Normal Mode”.
Press
Enter/Back
to save the new setting and return to the higher level menu. Press
Function/Escape
to
return to the higher level menu without saving changes. The delivery Smoke Mode Setting is “Turbo Mode”.
●
Invert Trigger Mode.
In the “Invert Trigger Mode” display press
Enter/Back
to show the current trigger mode
set. Use
Up
and
Down
buttons to move up and down to select “N/O Mode” (unit detects a normally open
circuit going closed to activate) or “N/C Mode” (unit detects a normally closed circuit going open to activate).
The Set, Trigger and Hold-off modes are always the same and changing this setting changes all 3 at once.
Press
Enter/Back
to save the new setting and return to the higher level menu. Press
Function/Escape
to
return to the higher level menu without saving changes. The delivery Trigger Mode Setting is “N/C Mode”.
●
Enable / Disable Battery.
In the “Enable / Disable Battery” display press
Enter/Back
to show the current
battery setting. Use the
Up
and
Down
buttons to move up and down to select “Disable” or “Enable”. Press
Enter/Back
to save the new setting and return to the higher level menu. Press
Function/Escape
to return to
the higher level menu without saving changes. The delivery Battery Setting is “Enable”.
NB: the function of
the battery switch is described in the “Battery Management” Section.
●
Enable / Disable ESM (Energy Saving Mode).
In the “Enable / Disable ESM” display press
Enter/Back
to
show the current ESM setting. Use the
Up
and
Down
buttons to move up and down to select “Disable” or
“Enable”. Press
Enter/Back
to save the new setting and return to the higher level menu. Press
Function/Escape
to return to the higher level menu without saving changes. The delivery ESM Setting is
“Disable”.
●
Smoke Delay.
In the “Smoke Delay” display press
Enter/Back
to show the current smoke delay set. Use the
Up
and
Down
buttons to move up and down to select a time between 0 and 60 seconds in 1 second
intervals. Press
Enter/Back
to save the new setting and return to the higher level menu. The delivery Smoke
Delay Setting is “0 seconds”.
●
Verify Timer.
In the “Verify Timer” display press
Enter/Back
to show the current verify time set. Use the
Up
and
Down
buttons to move up and down to select a time between 0 and 3600 seconds in 5 second
intervals. Press
Enter/Back
to save the new setting and return to the higher level menu. The delivery Smoke
Delay Setting is “0 seconds”.
●
EN Mode.
This is preset at manufacture and should only be altered by Concept Smoke Screen.