Cleaning the spray arms
It is necessary to clean the spray arms regularly. Calcium and dirt may block
nozzles and bearings of the spray arms.
• Check the outlet nozzle of the spray arms whether they are blocked by
food residues or not.
• If it is necessary, unscrew and remove the spray arms (Pic. 11). Wash them
under running water and then place them back.
• To dismantle the upper arm, hold the nut, turn the arm clockwise and
remove it.
• The INNOWASH upper spray arm can be detached into two parts. Grasp
the INNOWASH spray arm after being dismantled and pull it out as shown
in Pic. 12. Push the INNOWASH spray arm until it clicks to put the spray
arm back again.
• To dismantle the lower arm, remove the arm by lifting it upwards.
• Wash each spray arm in warm soapy water. To clean the nozzles use a fine
brush.
• Install the arms back after cleaning.
CAUTION!
One of the most common malfunctions is clogged spray arms. The filter is not properly inserted. Make sure the filter
system is locked properly after cleaning!
Cleaning the control panel and the surface of appliance
• Use only a soft damp cloth for cleaning.
• Do not use rough and sharp objects (e.g. steel wool) or aggressive detergents.
• Do not allow water to come in contact with the door lock of the appliance.
• To clean the control panel do not use a spray cleaner. It may cause damage to the door lock and electrical parts of
the appliance.
• Some paper towels can scratch the stainless steel of the control panel.
Cleaning the door of the appliance
• To clean the edges around the door, use only a soft damp cloth.
• Do not use any spray cleaners, they may damage the door lock and electrical parts of the appliance.
Properly secured filter
Poorly secured filter
Poorly secured filter