MORE SECURITY FOG OVER A LONGER PERIOD THAN ANY OTHER SYSTEM

FEATURES

• Competitive pricing
• Easy installation
• Simple integration into existing alarm systems
• Compact, rugged steel casing
• Guaranteed ‘No Residue’
• Intelligent consumable monitoring
• Wall or ceiling mount
• British and European standard compliant
• £10 million product and public liability insurance
• Full range of models producing up to 1500m

3

 

smoke per minute

OPERATION

• Inputs to accommodate ‘Set’, ‘Trigger’ and 
‘Hold-off’
• Simple smoke control 

CONSTRUCTION

• Unique machined steel heater-block
• FIREROD® cartridge heaters 

E-SERIES DATA

• 30(H) x 27(D) x 32(W) cm
• Weight 14 - 20 kg
• 230-volt, 2.8 kW
• 0.2 MMD particle

THE TECH SPEC

The EVOLUTION series of Concept Smoke Screen fog generators is 
exactly what the name suggests - Darwin’s principles proven.  This 
range of generators represents the pinnacle of our engineering 
excellence and experience. Every aspect of what a security fog 
generator is intended to do has been thought out, and the curre

nt 

range is the end result of 40 years of continuous application 
development. There is even a very good reason for the shape of 
the generators. The E-Series is exactly the right shape to be 
passed through a ceiling grid and mounted above a false ceiling

Our own installations have taught us that this is the optimal 
location for a security fog generator, both in terms of protecting 
the point of fog production, and in terms of the best way of   

  

introducing the fog itself - vertically down.

The range has advanced signalling capability, full fault awareness 
and the most flexible approach to installation options. The 
E-Series is in service, protecting property, with all manner of 
customers from home owners to large chains of retail stores.

DIGITAL INTERFACE

The E-Series is the most flexible 
range, offering control over all 
parameters. The generator can be 
tailored to exacting requirements

.

RUGGED DESIGN

Constructed to defence standards, 
the E-Series is built to last, and 
protect.

PRECISION ENGINEERING

The safest, driest fog on the market 
is achieved with our precision 
engineered heater block. Covered 
by a LIFETIME warranty.

THE E-SERIES

Fills large spaces in seconds       Smallest, lightest, most powerful model       Easy, seamless installation       NO residue

Содержание E+ Series

Страница 1: ...E SERIES INSTALLATION AND OPERATORS MANUAL v2011 1 CAN T SEE IT CAN T STEAL IT...

Страница 2: ...t Smoke Screen Limited 1 2 North End Swineshead Lincolnshire PE20 3LR Tel 44 01205 821111 Email info smoke screen co uk www smoke screen co uk IMPORTANT Please read this manual before commencing insta...

Страница 3: ...f 40 years of continuous application development There is even a very good reason for the shape of the generators The E Series is exactly the right shape to be passed through a ceiling grid and mounte...

Страница 4: ...inputs are open and the Hold off is open providing confirmation No Hold off attached Both Set and Trigger inputs are open If no Hold off is attached the Level 2 parameter HO Alarm on off should be cha...

Страница 5: ...nt the unit from firing in the event of a false panel alarm SMOKE PRODUCTION TIME The Smoke On time can be set in 15 second increments up to a maximum of 10 minutes parameter Level 1 If the unit goes...

Страница 6: ...old down the and p buttons to display Access Code 0 0 0 0 with a flashing cursor underline on the first digit Press q or p to select the first number Press to move to the second digit Repeat the above...

Страница 7: ...On off On H O R e t r i g On off On A l a r m I g n o r e 0 to 9 half second increments 0 4 5 secs 1 T e m p D i s p l a y On off Off N e t w o r k A d d r 1 to 999 001 E n g i n e e r Engineer Code...

Страница 8: ...ter a period with no button pressed in manual mode If any of the following conditions exist the display will alternate between the Ready Smoke display and the Conditions displays If more than one cond...

Страница 9: ...m m h h d d m m Alarm Panel Off Closed Contacts P o n s s m m h h d d m m Panel Set On Open Contacts P o f f s s m m h h d d m m Panel Set Off Closed Contacts H O o n s s m m h h d d m m Hold off On O...

Страница 10: ...djustment mode and check the following settings are correct Level 1 Smoke On Time 120 seconds Sound Rpt 5 min Sound Sil 2 hrs Aux Run 59 minutes Level 2 Smoke Test Off UPS Alarm Off On if UPS is fitte...

Страница 11: ...ed Relay rated at 1A 24vDC Contacts close when Smoke activated Contacts close when UPS is OK or UPS Alert is disabled Contacts closed when fluid level low Contacts closed when ready Additional Informa...

Страница 12: ...wFlu n o Ready n c Ready c Ready n o Notes Take care with Trigger and Set connections Do not cross connect ve and ve rails together PCB max output current is 250mA Alarm Panel Set Set Intruder Intrude...

Страница 13: ...NSTALLATION GUIDE Wall mounting slot Cable entry Carry handle and suspension bracket fitting Mains cable LED Display Fluid bottle Door lock hold off optional Interface optional Intruder alarm panel ho...

Страница 14: ...ceed to step 2 If the unit is to be mounted in the ceiling proceed to step 3 Fixing the mounting bracket First drill four holes using the mounting bracket as a template Then secure the bracket to the...

Страница 15: ...ut Put two nuts and washers on each bar leaving enough space in between for the units mounting bracket ceiling false roof Fixing the mounting bracket First remove the handle on top of the unit using a...

Страница 16: ...erfly nut and wiring case to expose a bank of connector blocks Carefully connect the wires to the corresponding connector block If no PIR is used link both Tamper PIR Finally the on board timer should...

Страница 17: ...racket ELM HP bracket E S e r ie s b r a c k e t Ducting bracket E Series suspension kit Wall mounted E Series aerosol M8 studding Zebedee M8 large washer M8 large washer M8 nut Unistrut M8 studding M...

Страница 18: ...Mounting Examples...

Отзывы: