INSTALLATION AND OPERATION
Before commencing installation of the S3B Sound Barrier please ensure that you have all of the equipment required.
1 x S3B Sound Barrier.
•
1 x Literature Pack.
•
You will also require:
12-volt DC supply and Connections into the alarm panel.
•
OVERVIEW
The S3B Sound Barrier is designed to form part of an existing intruder alarm system. It may also be configured as a
‘stand-alone’ system. The schematic shows the internal layout of the S3B Sound Barrier. The PCB and Battery pack
occupy one end of the device while the eight special speaks occupy the remainder.
TO REMOVE THE COVER
Remove two screws from the PCB end and release the end cap. Pull out the mesh screen to expose the speakers and
PCB.
MOUNTING POINTS
Pre-drilled holes on the back of the S3B Sound Barrier allow it to be mounted flat
against a wall or in a 90° corner.
CONNECTIONS
The sounder needs a 12-volt DC supply to charge the internal batteries. Fully
charged the sounder will work for up to 168 hrs off mains. If the sounder is to be
off mains for longer the Battery Enable Switch must be switched ‘Off’.
IMPORTANT:
1. Ear protection should be
worn during installation
and testing.
2. Sounder should always
be mounted high on
walls or on the ceiling -
recommended minimum
height is 2 metres.