Page
12
of
16
LED AND SOUND INDICATIONS
The Smoke Screen provides on-board status monitoring via an LED and a sounder. Indications displayed are:
LED colour
Buzzer sound
Output relay status
change
Indication meaning
●
Flash twice every 2 seconds
1 short beep every 5 seconds
Ready n/c to open.
Smoke Screen overheating*.
●
Flash once every 2 seconds
1 long beep every 60 seconds
Ready n/c to open.
Cover open and/or the external tamper is open/not jumpered.
●
Flash twice every 5 seconds
1 short beep every 5 seconds
UPS n/c to open.
UPS monitoring set to on and UPS power fail or UPS not
connected.
●
Flash once every 5 seconds
1 short beep every 5 seconds
Nil.
Mains power failure (UPS fitted).
●
Flashing
1 short beep every 5 seconds
Ready n/c to open.
Heater fault*.
●
On
Continuous beep for 30
seconds then 3 short beeps
every 5 minutes
Nil.
Smoke Screen heating to operating temperature*.
●
●
Alternating
None
Nil.
Smoke Screen in ‘Programming Mode’.
●
On
None
Ready n/c to closed.
Smoke Screen ready to operate.
●
Flashing
None
Nil.
Smoke Screen receiving ‘Alarm Set’ and ‘Trigger’ signals but
waiting for a ‘Hold Off’ to activate.
●
Flashing
1 beep every 2 seconds
Verification n/c to open.
Smoke Screen has activated and smoke has been produced
– indication will continue until both ‘Alarm Set’ and ‘Trigger’
are reset.
●
On
1 short beep every 5 minutes
Fluid status n/c to open
Low fluid
– first warning, Smoke Screen will still activate.
●
Flashing
1 long and 1 short beep every
5 minutes
Nil.
Empty fluid or fluid bag removed*.
* = Smoke Screen will not activate in this state.