CIRCUIT BOARD LAYOUT 

 

PCB   

 

 

Connection Terminals 

 
Mains fuse (10 Amp) 
 
 
 
 
 
 
 
 
 
 
 
 
 
Tamper Jumper 
 
 
Programming Dip Switches 1 & 2 
 
 
 
Activation test button

“PB1” 

 
Programming button “PB2” 
 
Indication LED 
 

GENERIC CONNECTION DIAGRAM 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

20130828-S30 Generic Connection Diagram-v2

 

 

 

 

Tamper 

 

 

Tamper 

 

 

0v (100mA) 

 

 

12v (100mA) 

 

 

Hold Off 

 

 

Hold Off 

 

 

Verification NO 

 

 

Verification NC 

 

 

Verification COM 

 

 

UPS Status NO 

 

 

UPS Status NC 

 

 

UPS Status COM 

 

 

Fluid Status NO 

 

 

Fluid Status NC 

 

 

Fluid Status COM 

 

 

Not Ready NC 

 

 

Not Ready NO 

 

 

Not Ready COM 

 

 

Trigger 

 

 

Trigger 

 

 

Alarm Set 

 

 

Alarm Set 

 

S30 Generic Connection Diagram

PIR or other

S30

Notes

 final confirm ation device

Tamper

Tamper

Tamper

Tamper

0v

0v DC

12v

12v DC

Alarm  Panel or sim ilar control device

Alarm

Hold Off

Alarm

Hold Off

Input 1

+ve

Verification n/o

Machine activating

Verification n/c

Ground

Verification com

Input 2

+ve

UPS n/o

UPS failure

UPS n/c

Ground

UPS com

Input 3

+ve

Low  n/o

Fluid low

Low  n/c

Ground

Low  com

Input 4

Ready n/c

Machine ready 

+ve

Ready n/o

to activate

Ground

Ready com

Set

Trigger

Set

Trigger

Intruder

Alarm

Intruder

Alarm

"Tamper" changes state if the S30 case or external tamper 
is open.  n/c and n/o show n are w hen the case is closed.

Outputs

"Ready" changes state if there is a critical fault.  n/c and n/o 
show n are w hen the S30 is w orking correctly.

"Low " changes state if the S30 fluid is low .  n/c and n/o 
show n are w hen there is fluid available.

"UPS" changes state if there is a UPS fault.  n/c and n/o 
show n are w hen the UPS is w orking correctly.

Alarm Panel detects n/o 
circuit going closed to 
signal the specified event.

Alarm Panel ouput contacts 
should be clean relay 
closed pairs energising 
open on set / intruder.

"Verification" changes state w hen the S30 fires.  n/c and 
n/o show n are w hen the S30 is not firing.

"Alarm Set", "Trigger" and "Hold Off" should be connected 
to normally closed clean contacts going open to fire the 
S30.  All 3 must be open to fire the S30.

DC output for additional device.  Total S30 output must not 
be greater than 100mA.

See note for "Alarm Set" and "Trigger".  Leave open if no 
device fitted.

Содержание SENTINEL S30

Страница 1: ...Page 1 of 16 SENTINEL S30 INSTALLATION AND OPERATION MANUAL Version 16 December 2013 CAN T SEE IT CAN T STEAL IT ...

Страница 2: ...l help Once again thank you for your decision we hope that it s one that never needs to be tested Carl Gibbard Managing Director HOW DOES YOUR SMOKE SCREEN WORK Your Smoke Screen heats a non toxic fluid under pressure to create smoke or more accurately a thermally generated fog that obscures visibility to discourage intruders from entering your premises This fog is very persistent and will stay su...

Страница 3: ...lation procedure 5 Access 6 Mounting 6 Controlling the smoke 7 Circuit board layout 8 Generic connection diagram 8 Un interrupted Power Supply UPS 9 Tamper 9 Fluid management 9 Programming 10 Operation 10 Testing 11 LED and sound indications 12 Action after every activation 13 Servicing and fluid replenishment 13 FAQ 13 Installer notes 14 ...

Страница 4: ...tic STANDARD INSTALLATION A standard installation is configured in the following way The Smoke Screen wall or ceiling mounted in the appropriate location A Hold off PIR or similar device located within the same area as the Smoke Screen providing a confirmation signal to the Smoke Screen to start smoke production A Set command supplied by an Alarm Control Panel or equivalent in the form of an N C N...

Страница 5: ...above the floor over the area to be protected and using a straight nozzle The maximum mounting height above floor level is 3 metres and there should be no obstacle within 1 metre of the smoke output nozzle INSTALLATION PROCEDURE 1 Site the Smoke Screen and fix the bracket to the wall or ceiling as appropriate 2 For wall mounting leave minimum 150mm clearance to ceiling 3 Fasten the Smoke Screen to...

Страница 6: ...8mm washer 4 x 25mm washer 6 x full nut 2 x drop in anchor 2 x channel nuts Wall mounting The Smoke Screen can be wall mounted to fire horizontally or angled to fire down at 15 30 or 45 degrees using a simple wall bracket 1 that should be attached to a suitable wall using appropriate fixings We recommend as high a position as possible for aesthetic and security anti tamper reasons but no higher th...

Страница 7: ...nput connections on the Smoke Screen Alarm Set Trigger and Hold Off that should be connected to clean contacts For the Smoke Screen to produce smoke all 3 sets of connections must be open circuit this can be changed to closed as described under Trigger Mode in the Programming section If one set of connections is closed circuit then the Smoke Screen is prevented from producing smoke Hence the produ...

Страница 8: ... Input 4 Ready n c Machine ready ve Ready n o to activate Ground Ready com Set Trigger Set Trigger Intruder Alarm Intruder Alarm Tamper changes state if the S30 case or external tamper is open n c and n o show n are w hen the case is closed Outputs Ready changes state if there is a critical fault n c and n o show n are w hen the S30 is w orking correctly Low changes state if the S30 fluid is low n...

Страница 9: ...es not prevent the Smoke Screen from activating FLUID MANAGEMENT Fluid capacity The Smoke Screen can be fitted with a 500ml transparent bag containing Smoke Fluid Fluid monitoring The Fluid Level is monitored using an on board timer that measures the amount of fluid used by timing consumption when the Smoke Screen is activated Each time the bag clamp is unfastened and the fluid bag is replaced the...

Страница 10: ...n on and off When finished change Dip Switch 2 to OFF Note If there is a UPS fault or no UPS is fitted the LED will flash twice every 5 seconds accompanied by 3 short beeps every 30 seconds Trigger Mode The delivery settings of the 3 sets of input connections on the Smoke Screen Alarm Set Trigger and Hold Off are normally closed going open to activate Dip 1 set to ON These can be changed to normal...

Страница 11: ...rigger contacts are closed Smoke Screen stand alone test The Smoke Screen can be tested when it is ready to operate indicated by a steady green LED by pressing the button on the PCB marked PB1 This produces smoke only whilst the button is pressed NB this does not check that the inputs and connections to the Smoke Screen are correct Note When mains power is switched on even if the Smoke Screen is a...

Страница 12: ...Ready n c to open Heater fault On Continuous beep for 30 seconds then 3 short beeps every 5 minutes Nil Smoke Screen heating to operating temperature Alternating None Nil Smoke Screen in Programming Mode On None Ready n c to closed Smoke Screen ready to operate Flashing None Nil Smoke Screen receiving Alarm Set and Trigger signals but waiting for a Hold Off to activate Flashing 1 beep every 2 seco...

Страница 13: ...is serviced replenished by an engineer certified by the manufacturer If you are unsure ask the engineer for his certification ID card It is recommended that the Smoke Screen is checked and the fluid changed annually by the installer or Concept Smoke Screen Always ensure that the Smoke Screen has sufficient fluid or it will not produce smoke when needed It is recommended that the installer or Conce...

Страница 14: ...Page 14 of 16 INSTALLER NOTES ...

Страница 15: ...Page 15 of 16 ...

Страница 16: ...Page 16 of 16 Concept Smoke Screen Limited 1 2 North End Swineshead Lincolnshire PE20 3LR United Kingdom Tel 44 0 1205 821111 Fax 44 0 1205 820316 Email info smoke screen co uk www smoke screen co uk ...

Отзывы: