S
PECIFICATIONS
: G
AS
T
RAC
GasTrac Process Air Heater
UGD014/0497
2-8
D
ESCRIPTION
H
W
D
Dimensions
H
W
D
Weight
Air inlet/outlet
in./cm
in./cm
in./cm
lbs/kg
diameter in./cm
CGT700HH Horizontal Model
61/154.9
37/93.9
74/187.9
1115/505.7
12/30
CGT700HV Upright Model
67/170.2
39/99
64/162.6
1115/505.7
12/30
CGT500HH Horizontal Model
61/154.9
37/93.9
64/162.6
880/399.2
8/20.3
CGT500HV Upright Model
65/165.1
39/99
64/162.6
880/399.2
8/20.3
CGT350HH Horizontal Model
54/137.2
29/73.7
66/167.6
695/315.2
8/20.3
CGT350HV Upright Model
58/147.3
31/78.7
56/142.2
695/315.2
8/20.3
Remotable GasTrac control
3.5/8.9
12.5/31.7
6/15.2
—
—
W
H
W
D
CGTHH horizontal model
CGTHV upright model
H
D
Remotable
GasTrac control
CGT700 models
CGT500 models
CGT350 models
General
Temperature range
250-350˚F / 122-177˚C
250-350˚F / 122-177˚C
250-350˚F / 122-177˚C
Maximum Flue Temperature
750˚F / 399˚C
750˚F / 399˚C
750˚F / 399˚C
Combustion blower
1.5 Hp Peripheral
1 Hp Peripheral
1 Hp Peripheral
Ignition source
Spark igniter, interrupted
Spark igniter, interrupted
Spark igniter, interrupted
Burner type
Metal-ceramic
Metal-ceramic
Metal-ceramic
Minimum burner capacity
150,000 BTU/hr
125,000 BTU/hr
90,000 BTU/hr
Maximum burner capacity
700,000 BTU/hr
500,000 BTU/hr
350,000 BTU/hr
Gas consumption
230 CFH @ 250˚F/1200 CFM
150 CFH @ 250˚F/800 CFM
105 CFH @ 250˚F/600 CFM
675 CFH @ 350˚F/1800 CFM
465 CFH @ 350˚F/1200 CFM
325 CFH @ 350˚F/800 CFM
Gas pressure to regulator
10 - 20 inches of water / 2.49 - 4.98 kilopascals
Gas pressure from regulator
4 - 7 inches of water / 0.99 - 1.74 kilopascals
Gas heating value
1000 BTU/ft
3
Electrical
Available voltages / Total Amps
240 V/3 phase/60 Hz
4.8 A
2.5 A
2.0 A
380 V/3 phase/50 Hz
3.0 A
1.6 A
1.3 A
415 V/3 phase/50 Hz
2.7 A
1.5 A
1.2 A
480 V/3 phase/60 Hz
2.4 A
1.3 A
1.0 A
Total Kilowatts
1.9 kw
1.0 kw
0.8 kw
Emissions (all models)
Primary excess air
10% - 30%
Oxygen (O
2
) [Ideal 3%-4%]
2% - 5% acceptable range
Carbon Dioxide (CO
2
)
9% - 10.5%
Carbon Monoxide (CO)
< 10 ppm corrected to 3% O
2
NOX
< 20 ppm corrected to 3% O
2
Unburned hydrocarbons
< 10 ppm corrected to 3% O
2
NOTE: Elevations 3000 feet above sea level must be specified at time of purchase.
All GasTrac models meet:
UL 372, UL 795, FM, CGA,
AGA, NFPA 54, NFPA 79,
NFPA 86 and IAS