background image

91300366 - Rev.00 - 15.11.18

Rule of the first saved Remote control:

When programming remote controls the following rule is applied: if 

the first remote to be saved is a rolling code type, the receiver will 

subsequently accept only rolling code remotes (thus ensuring greater 

anti-intrusion security); if the first remote to be saved is a fixed code 

type, the receiver will accept both fixed and rolling code remotes, 

although only the fixed part of the latter will be identified.

For  the 

deletion

  of  remote  control  codes 

please check the installation and user ma

-

nual  or  the  video  with  the  detailed  pro

-

gramming tutorial.

L) RESET

If it becomes necessary to 

reset

 the control unit to restore the factory 

settings, press the 

SELECT

 and 

SET

 keys together; this will cause all 

the 

indicator LEDs

 to light simultaneously followed immediately by 

the control unit switching off.

 WARNING!: 

by the above mentioned procedure the stored re

-

mote codes 

WILL NOT be deleted

; where necessary follow the above 

mentioned procedure of deletion.

G)  PAUSE TIME - Automatic closing time programming

The automatic closing is factory disabled; 

to  enable  it  after  a  fixed  period  of  time 

(max. 4 min.) proceed as follow:

1.  By  the  key 

SELECT

,  position  yourself  on  the  blinking 

LED L6 

“PAUSE TIME”

2.  Press once the key 

SET

;

3.  Wait for a desired time interval;

4.  Press the key 

SET

 again;

MAX 4 MIN

5.  The 

LED L6

 will remain steady on and that period of time would 

be set as time interval.

H)  Remote control code programming (total opening)

PP CHANNEL 

gives  an  input  to  activate  the  total 

stroke stored.

PPED CHANNEL 

gives an input to activate the pede

-

strian or partial stroke the total stroke

Up to 120 remote controls can be memori

-

zed in the control unit receiver. 

Its programming is performed as follow:

1.  By  the  key 

SELECT

,  position  yourself  on  the  blinking 

LED L3 

“CODE TX”

2.  Press key 

SET

 once to memorize the 

PP channel

3.  Send the selected code with your remote control;

4.  The 

LED L3

 will remain steady on for a second to indicate that 

programming has been completed.

5.  The 

LED L3

 starts to blink again to indicate that you have 10 

additional sec. to store a new code; 

6  On expiry of those 10 sec. the 

LED L3

 will remain steady on.

I)  Remote control code programming (partial/pedestrian ope-

ning)

1.  By  the  key 

SELECT

,  position  yourself  on  the  blinking 

LED L3 

“CODE TX”

;

2.  Press key 

SET

 twice to memorize the 

PPED channel

;

3.  Send the selected code with your remote control;

4.  The 

LED L3

 will remain steady on for a second to indicate that 

programming has been completed. The extra time of 10 sec. to 

store a new PPED channel is then preview as for the PP chan

-

nel.

To watch videos you will need to have an internet connection and to install in your Tablet or Smartphone a 

QR code 

reader

, available on 

APPLESTORE

 for iOs devices or on 

GOOGLE PLAY

 for Android devices.