This section will provide the essential information for the setting-up
of the control unit.
PROGRAMMING KEYS:
SELECT:
this key allows you to select the type of function to be
enabled; the selection is indicated by the LED flashing.
By pressing the key, you can scroll through the menu and position
yourself on the desired function.
SET:
this key allows the activation of the type of function chosen with
the SELECT key.
Programming enabled only in non-active safeties conditions.
Before starting the programming, it will be necessary to set up the
automation.
A)
Make sure that the safety inputs N.C. are not open:
1.
Photocell input
DS1
2.
Photocell input
DS2
3.
Block input
STOP
B) OPENING DIRECTION:
If the opening logic must be reversed, plea
-
se proceed as follows:
1. By the key
SELECT
, position yourself on the blinking LED
L1
“DIR”;
2. Press the key
SET
to reverse the opening direction.
LED ON: it opens to the left.
LED OFF: it opens to the RIGHT
(default configuration).
C) TRIMMERS ADJUSTMENTS:
CU 24V 1M
Position the SPEED trimmer
all turned clockwise and the
SENS trimmer all turned coun
-
ter-clockwise.
CU 230V 1M
Position the FORCE trimmer all
turned clockwise and the SLOW
trimmer at the middle, turning
it counter-clockwise towards the
“ - “.
The trimmer adjustments must be carried out in compliance
with the EN-12453 legislation, regulating the impact forces.
After the preliminary checks, the control unit programming can be
carried out.
D)
MOTOR TIME: regulation of the stroke and of the deceleration points.
QUICK START GUIDE FOR INSTALLATION AND PROGRAMMING OF CONTROL UNITS:
CU 24V 1M e CU 230V 1M
Use the QR-CODE option to watch the “step-by-step” videos tutorials, available on the YouTube channel Comunello TV
Starting condition: gate leaf in closed position.
M1
1. By the key
SELECT
, position yourself on
the blinking
LED L5 “MOTOR TIME”
;
2. Then press the key
SET
to start the pro-
cedure.
LEAF IN OPENING PHASE
3.
MOTOR 1
starts the opening phase;
4. When the desired deceleration starting
point is reached press the
SET
key (the leaf
continues its stroke at a decelerated speed);
5. Press
SET
key to determinate the ope
-
ning end stop.
LEAF IN CLOSING PHASE
6. A
MOTOR 1
starts the closing phase;
7. When the desired deceleration starting
point is reached press the
SET
key (the leaf
continues its stroke at a decelerated spe
-
ed);
8. Press
SET
key to determinate the closing
end stop;
9. The configuration is completed.
E) AUTO PROGRAM - automatic setting of the stroke and of the
deceleration points (only available for CU 24V 1M)
With the function in
LED L7 “AUTO PROGRAM”
it is automatically set the total stroke and the
deceleration points.
ATTENTION:
the use of end stops is mandatory.
Please check the installation and user manual or the video with the
detailed programming tutorial.
F) STEP-BY-STEP OPERATING LOGIC
This function allows to switch the operating logic of input sent from
pushbuttons or remote controls from the “Step-by-Step” (enabled
as-shipped) to “Open-Close”:
STEP BY STEP LED ON
OPEN-CLOSE LED OFF
1st input -->
OPEN
2nd input -->
STOP
3rd input -->
CLOSE
4th input -->
STOP
1st input -->
OPEN
2nd input -->
CLOSE
3rd input -->
OPEN
4th input -->
CLOSE
To change the logic, proceed as follow:
1. By the key
SELECT
, position yourself on the blinking
LED L2
“STEP BY STEP”
;
2. Press the key
SET
;
3. The
LED L2
will turn off and programming will be completed.