Installing the DeviceMaster 500 and the SICK LMS Scanner (Windows):
2000472 Rev. C
1-Port Custom Embedded Bulk (99474-9) Installation
on Page 9 to complete the installation.
1-Port Custom Embedded Bulk (99474-9) Installation
Use the following procedure to set up the 1-port custom embedded bulk
DeviceMaster 500 and LMS scanner at 500K baud.
•
If necessary, build the serial ribbon cable.
•
Mount the DeviceMaster 500 and optionally install light pipes (Page 5).
•
Attach the network and serial cables (Page 6).
•
Connect the power and verify installation (Page 7).
Building the Serial
Ribbon Cable
Use the following information to build a DB9 serial ribbon cable to connect to the
DeviceMaster 500 1-Port embedded IDC10 connector (
J3
).
Status
If the LED is lit, it indicates that the DeviceMaster 500 has
power and it has completed the boot cycle
.
Note:
The
Status
LED flashes while booting and it takes
approximately 15 seconds for the Bootloader to
complete the boot cycle.
When the Bootloader
completes the cycle, the LED has a solid, steady light
that blinks approximately every 30 seconds.
LED Descriptions 1-Port Enclosed
J3 Header
RS-232
RS-422
RS-485
1
CD
Not used Not used
2
DSR
Not used Not used
3
RxD
RxD-
Not used
4
RTS
TxD+
TRX+
5
TxD
TxD-
TRX-
6
CTS
RxD+
Not used
7
DTR
Not used Not used
8
RI
Not used Not used
9
GND
Not used Not used
10
Not connected
Pin 1
Pin 6
1 2
9 10
Ribbon Cable
10-Pin
Socket
Pin 5
Pin 9
DB9
Male
J3